B. Full Reline With Outside Air - Vertical
NOTE:
Check clearances carefully for this type of
installation to ensure adequate room for outside air
venting.
NOTE: In Canada this fireplace insert must be installed
with a continuous chimney liner extending from the fire-
place insert to the top of the chimney. The chimney liner
must conform to the Class 3 requirements of CAN/ULC-
S635, Standard for Lining Systems for Existing Masonry
or Factory-Built Chimneys and Vents, or CAN/ULC-
S640, Standard for Lining Systems for New Masonry
Chimneys.
18
NOTE; Use metal plate around
exhaust vent pipe and seal all
edges with non-flammable insula-
tion such as mineral wool or
ceramic.
Do not use high temperature caulk-
ing materials to seal any edge to
prevent furture serviceability.
Figure 18.1
NOTE: In Canada only a full reline is allowed per ULC
S628, ORD ULC C1482-M1990.
305mm min.
above
305mm min.
below
Check building codes prior to installation.
• Installation MUST comply with local, regional, state and
national codes and regulations.
• Consult local building, fire officials or authorities having juris-
diction about restrictions, installation inspection, and permits.
7014-285A