OPERATIONAL PERFORMANCE
Function:
Accuracy:
• Depth
±1% of full scale
• Timers
1 second per day
Dive Counter:
• AIR/NX and GAUGE displays Dives #1 to 24.
• Resets to Dive #1, upon diving (after 24 hours with no dives).
Dive Log Mode:
• Stores 24 most recent AIR/NX and GAUGE dives in memory for viewing.
• After 24 dives, adds 25th dive in memory and deletes the older dive.
Altitude:
• Operational from sea level to 14,000 feet (4,270 meters) elevation
• Measures every 15 minutes while in Surface Modes.
• Does not measure ambient pressure when wet.
• Compensates for Altitudes above sea level beginning at 3,001 feet (916 meters) elevation and every 1,000 feet (305 meters) higher.
Conservative Factor:
• Reduces AIR/NX NDLs to those for the Altitude 3,000 feet (915 meters) higher.
Power:
• Battery (QTY:1)
compatible with lithium (CR123A: Duracel® or Panosonic™) or rechargeable lithium (RCR123A: Nitecore®, Olight™; Delipow®)
batteries.
• Shelf life
Up to 7 years (when shipped from factory in Deep Sleep mode)
Power Saver Mode (surface):
• Activates and turns screen off when 2 minutes elapse on surface with no button operations.
• Resume operation from Power Saver Mode by pressing any button.
Battery Indication:
• Green (Good) - Green Icon displays on the Suface Main. No battery icon during the dive.
• Amber (Warning) - Amber Icon solid on the Surface and Dive Main screens. Battery change is recommended. Brightness level will automatically be
limited to 60% maximum.
• Red (Alarm) - Red Icon flashing on the Surface and Dive Main screens. If during a dive, the message LOW BATTERY flashes. If on the surface, the
message CHANGE BATTERY flashes until the unit shuts off. The battery must be changed before using your Sage
Operating Temperature:
• Out of the water - - between 20 °F and 140 °F (-6 and 60 °C).
• In the water - - between 28 °F and 95 °F (-2 and 35 °C).
• At extremely low temperatures, the LCD may become sluggish, but this will not affect it's accuracy.
• If stored or transported at temperatures below freezing, you should warm the unit and its battery with body heat before diving.
Storage Temperature:
Out of the water (in storage case provided - - between 14 °F and 158 °F (-8 and 70 °C).
Working Pressure:
4000 PSI, 276 BAR