Communication Standard - October 1997. This format will send the account code along with its data
transmission. The transmission will look similar to the following at the receiver.
NOTE: This section shall sync with PowerSeries Neo panels version 1.00 or higher.
Example:
Nri0 ET001 where: N = New Event; ri0 = Partition/Area identifier; ET = Panel Absent Trouble; 001 =
Zone 001.

Communications Reporting Codes

Event
[023] Panel Absent Trouble
[024] Panel Absent Trouble
Restore
[026] Ethernet 1 Test
Transmission
[027] Ethernet 2 Test
Transmission
[028] Cellular 1 Test
Transmission
[029] Cellular 2 Test
Transmission
[030] FTC Restore
[023] Panel Absent Trouble
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with the
panel have been lost for more than 60 seconds.
[024] Panel Absent Trouble Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur when communications with the
control panel have resumed.
[025] Radio Activation Restore
Default (FF)
Program 00 to disable this event or FF to enable. This event will occur in North American cellular com-
municators when the unit has been programmed by Connect 24.

System Test Options

Test Transmissions to Primary Receiver, with Backup to Secondary Receiver:
Set Ethernet section [026] to (FF); [027] to (00). Set cellular section [028] to (FF); [029] to (00).
If the test transmission fails to the primary receiver it will back up to the secondary receiver.
l
If the test transmission fails to the secondary receiver an FTC trouble will be generated.
l
Test Transmission Unique to Primary and Secondary Receivers:
Set Ethernet section [026] to (FF); [027] to (FF). Set cellular section [028] to (FF); [029] to (FF).
The module will send periodic test transmissions to each receiver independently, with no backups.
l
If the test transmission fails to any of the programmed receivers, an FTC trouble will be generated.
l
Alternate Test Transmission:
Alternate test transmission can be enabled or disabled in section [005] toggle option [7].
Alternate Test Transmission with Backup Receivers:
Set Ethernet section [026] to (FF); [027] to (00). Set cellular section [028] to (FF); [029] to (00).
Interval 1:
If the test transmission fails to the primary receiver, it will back up to the secondary receiver.
l
If the test transmission fails to the secondary receiver, an FTC trouble will be generated.
l
Table 9: Communications Reporting Codes
SIA
SIA
Reporting
Identifier
Code
ET
0001
ER
0001
RP
0001
RP
0002
RP
0003
RP
0004
YK
0001
23
CID
CID
Event
Reporting
Qualifier
Code
Code
1
3
3
3
1
6
1
6
1
6
1
6
3
3
CID
CID
User/Zone
55
001
55
001
A3
951
A3
952
A3
955
A3
956
54
001