Interval 2:
If the test transmission fails to the secondary receiver, it will back up to the primary receiver.
l
If the test transmission fails to the primary receiver, an FTC trouble will be generated.
l
Test Transmission Unique to Primary and Secondary Receivers:
Set Ethernet section [026] to (FF); [027] to (FF). Set cellular section [028] to (FF); [029] to (FF).
Interval 1:
The module will send periodic test transmissions to primary receivers (Ethernet primary and cellular
l
primary) independently, with no backups.
If the test transmission fails to any of the programmed primary receivers, an FTC trouble will be gen-
l
erated
Interval 2:
The module will send periodic test transmissions to secondary receivers (Ethernet secondary and cel-
lular secondary) independently, with no backups.
If the test transmission fails to any of the programmed secondary receivers, an FTC trouble will be
l
generated
[026] Ethernet 1 Test Transmission
Default (FF)
Program 00 to disable this event transmission or FF to enable. See system test options (previous page)
for details on settings.
[027] Ethernet 2 Test Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See system test options (previous page)
for details on settings.
[028] Cellular 1 Test Transmission
Default (FF)
Program 00 to disable this event transmission or FF to enable. See system test options (previous page)
for details on settings.
[029] Cellular 2 Test Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See system test options (previous page)
for details on settings.
NOTE: The time interval (in minutes) between periodic tests is programmed in section [125] (Ethernet)
and section [225] (cellular).
[030] FTC Restore
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when an FTC
Trouble on the system restores.
[033] Communicator Firmware Update Begin
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when a com-
municator firmware update begins.
[034] Communicator Firmware Update Success
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when a com-
municator firmware update has completed successfuly.
Event
[037] System FW Update Fail
NOTE: The communicator will report ´System Update Fail´ only if the panel becomes offline after a
remote firmware update session has started.
[095] SA Incoming Local Port
Default (0C14/3092)
Table 10: System Firmware Update Failure
SIA
SIA
Identifier
ReportingCode
LU
0000
24
CID
CID
Event
Reporting
Qualifier
Code
Code
1
9
CID
CID
User/Zone
04
003