Sms Commands; Communicator Status Leds; Yellow Trouble Led; Panel Supervision Trouble (2 Flashes) - DSC TL280LE Installation Manual

Internet and lte/hspa dual-path alarm communicator;lte/hspa alarm communicator;cellular alarm communicator;internet and hspa dual-path alarm communicator; internet alarm communicator
Hide thumbs Also See for TL280LE:
Table of Contents

Advertisement

through programming section [851].
The security system only responds to SMS messages sent from designated phone numbers (pro-
grammed in section [851]>[311]-[328]).

SMS Commands

Stay arm the system
l
Away arm the system
l
Night arm the system
l
Disarm the system
l
Activate command output 1
l
Activate command output 2
l
Activate command output 3
l
Activate command output 4
l
Deactivate command output 1
l
Deactivate command output 2
l
Deactivate command output 3
l
Deactivate command output 4
l
System status request
l
Alarm memory request
l
Zone bypass
l
Zone unbypass
l
SMS text messages must be formatted as follows:
<function name><space><partition #><space><access code>
(e.g., Stay Arm partition 1 1234). Once the command is received and executed by the alarm system, a
confirmation text message is received.
NOTE: For more information about SMS commands and control functions, refer to the Neo 1.1 User
Manual.
The communicator has four on-board LED indicators. These include one yellow trouble LED, one red
network connection status LED and two green signal strength LEDs. The LED meaning is described in
this section.

Yellow Trouble LED

This yellow LED will flash to indicate a trouble on the unit. The number of flashes indicates the type of
trouble. See the table below for the coded flashes and the conditions which will activate the trouble status
LED.
# of
Flashes
2
Panel Supervision Trouble
4
Not Applicable
5
Cellular Trouble
6
Ethernet Trouble
7
Receiver Not Available Trouble
NOTE: Only the highest priority trouble (2 flashes is the highest priority trouble) is indicated. When this
trouble is restored, the next highest trouble will indicate, if present. This will continue until all
troubles have been cleared (yellow LED is not flashing).
The following paragraphs describe the conditions associated with the trouble indicated:

Panel Supervision Trouble (2 Flashes)

This trouble will be indicated when communication between the communicator module and the panel
fails. If the module can not communicate with the panel (e.g., loss of power to the panel) the com-
municator will send the 'Panel Absent Trouble Event' message to the central station receiver. When com-
munication returns, a 'Panel Absent Restore Event' is sent by the communicator to the central station
receiver. The reporting codes are ET0001 for trouble and ER0001 for restore. The panel absent event
always uses the primary receiver account code when communicating to the central station.

Communicator Status LEDs

Table 5: Yellow Trouble Status LED
Trouble
Flashes
# of
8
Receiver Supervision Trouble
9
FTC Trouble
10
C24 Communications Configuration Failure
12
Module Configuration Trouble
14
Trouble