Kubota u15-3 Workshop Manual page 172

Table of Contents

Advertisement

WSM U15-3
2) Check battery voltage at (+) terminal of harness cou-
pler.
If no battery voltage, check the fuse and continuity of
wireharness.
Sample data is 0.979V.
3) Water temperature sensor check
• Disconnect the coupler from the water tempera-
ture sensor and measure the resistance referring
to the figure at right.
The temperature vs. resistance curve must meet
the criteria listed below.
°
Temp (
C)
-20
40
100
Resistance (k )
18.80 ± 12.6%
1.136 ± 8.4%
0.1553 ± 4.5%
II-152
Water temp. vs Sensor resistance
Water temp. (°C)