Meter Structure - Kubota u15-3 Workshop Manual

Table of Contents

Advertisement

4. Meter structure

Fuel meter
(1) Indicator is of movable magnet type (MG-23)
and vibration-proof.
(2) Performance is as per JIS D5606.
(3) The scale graduations other than E, F and 1/2
are dummy.
Graduation specifications
Graduation
Allowable error ( )
Resistance value ( )
Test voltage:
Test temperature:20 ± 5 °C
Test order :
Point F
Point E
Details of counter
White number on black background
White number on black background
White number on black background
Indicator display
Flashing in green every 2 seconds
Nippon Amp
(1) Illumi (+)
Code No.
(2) Engine hydraulic
(3) Charge
(4) Empty
(5) Ground (lamp)
(6) Bi-speed travel
(7) Glow
(8) Power (+)
(9) Fuel short alarm
(10) Empty
II-129
WSM U15-3
F
(1/2)
+7.5
-
0
10
(38)
DC14.5 ± 0.5 V
Order of OFF
F
E
(Wait for longer than 3 minutes
before inspection.)
Points E and F on the scale
White number on black background
White number on black background
Black number on white background
Pin arrangement
(11) Empty
(12) Empty
(13) Meter power
(14) Fuel meter
(15) Illumi, meter GND
(16) Empty
(17) HM GND
(18) Empty
(19) Empty
(20) Empty
E
0
-7.5
90

Advertisement

Table of Contents
loading