7) Hand off from the travel high-low SW button.
OFF
(7)
AC
Start
(4)
(6)
8) Pull up the lever lock SW (OFF position)
No battery current flows in this system and so the travel motor runs at low speed even after leaving the
machine previously at high speed conditions.
OFF
(7)
AC
Start
(4)
(6)
Note :
Lever lock SW (8) was not installed as shown above for the early production machines. It was connected
with unload valve solenoid only.
Therefore, in these machines, travel speed won't be reset to low range with the lever lock SW OFF con-
dition.
(8)
ON
(10)
(2)
(9)
(8)
OFF
(10)
(2)
(9)
II-125
(3)
OFF
(1)
(5)
(3)
(1)
(5)