Service Port System - Kubota u15-3 Workshop Manual

Table of Contents

Advertisement

WSM U15-3
l. Service port system
1. Component layout
This pedal is used to operate attachments
such as breakers.
(1) Service port pedal
(A) Sends oil to the port (A)
(B) Sends oil to the port (B)
(1) Port (A)
(2) Port (B)
• Push the right part of the pedal ( ) to
send oil to the port (A).
• Push the left part of the pedal ( ) to send
oil to the port (B).
Max. Flow Volume
Theoretical L min.
Max. Pressure MPa
(kgf/cm2)
IMPORTANT:
• When the service port is not used for a
long period, dirt particles can settle in the
lower part of the service port lines.
When the plugs on the service port lines
are removed to connect attachments,
drain approx. 100 cc of oil per side.
Concerning the choice of a breaker, con-
tact your dealer.
27.0
18.6 (190)
II-108
NOTE:
• When the service port is not in use, fold
the service port pedal forward. The pedal
gets fixed and can be used as footrest.
(1) Service port pedal (A) "Fix"