4) Continuity check
• Turn the key switch to the OFF position.
• Disconnect the meter coupler .
• Disconnect the glow relay coupler .
1. Check for continuity between the auto
glow relay coupler
and the glow relay coupler CN terminal
[CN17-1].
2. Check for continuity between the auto
glow relay coupler
and the glow relay coupler
[CN17-2].
3. Check for continuity between the glow
relay coupler terminal [CN17-3] and the
glow plug coupler.
4. Check for continuity between the glow
relay coupler terminal [CN17-4] and the
battery's positive (+) terminal.
5) Glow relay check
1. Glow relay
Code No. : T1060-33711
2. Disconnect the glow relay coupler. Mea-
sure the resistance between points (1)
and (2) on the glow relay alone.
(Relay coil resistance)
Specification
Actual measurement(Sample)
3. Apply 12 V between points (1) and (2) of
the glow relay to check for continuity
between points (3) and (4).
terminal [CN300-5]
terminal [CN300-3]
terminal
52 - 80
About 58
II-143
WSM U15-3
3
3
2
2
1
1
6
6
5
5
4
4
Battery