POTENTIAL OPERATING ISSUES
Error
Message
Code
56
Entered span gas concentration
is out of range - please edit and
try again
57
Operation failed; invalid object
type
58
Operation failed; CRC
calculation timeout
59
Operation failed; a session has
already been opened by another
user
60
The session has expired - new
user login required
61
Not used
62
Not used
63
Operation failed; CRC error
occurred for safe data.
64
Operation failed; CRC error
occurred
for non-safe data.
65
Operation failed; session does
not exist; user login required
66
Operation failed; CCB did not
respond within the expected
time interval.
67
Configuration read / write
request failed; FLASH memory
operation timeout
Pt. No. 2400M2566_1_EN
Possible Cause
Remedial Action
The span gas
1. Check the configured limits for span gas
selected is not within
concentration.
the configured limits
2. Obtain an alternative span gas that is within
the limits.
3. Retry the operation.
There has been a
1. Please retry the operation.
communication error
2. If still unsuccessful, on the front panel, press
between the CCB and
the Accept and Reset buttons together for 10 s,
COB
which will restart the COB.
3. If the error has not cleared, if possible cycle
the power to the system.
4. If the problem persists, please contact your
local service representative.
There has been a file
1. Please retry the operation.
transfer error
2. If still unsuccessful, on the front panel, press
between the CCB and
the Accept and Reset buttons together for 10 s,
COB
which will restart the COB.
3. If the error has not cleared, if possible cycle
the power to the system.
4. If the problem persists, please contact your
local service representative.
Another user may be
1. Check if another user is logged in.
logged in via one of
2. If your requirement takes priority, you have
the alternative
the option to terminate the existing (other
interfaces (local
user's) session.
Touchscreen or PC
Configuration
Software)
A user login will time
The system will automatically request a new
out after 20 minutes
login
of inactivity
Refer to Error 2
Refer to Error 2
———//———
————————//————————
User login is required
The system automatically requests a new login.
before carrying out
The user may have been remotely logged out
the intended
by another user.
operation
Refer to Error 2
Refer to Error 2
During configuration,
1. Retry the operation.
the CCB was unable
2. If the error has not cleared, if possible cycle
to read or write a
the power to the system.
value from / to non-
3. If the problem persists, please contact your
volatile memory
local service representative.
68
Sys
Sys
Fail
Fault
Relay
Relay
X
X
X
X
X
X
X
Touchpoint Pro
Operating Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tppr

Table of Contents