Error Mode

A. If an error occurs before or during operation, the error will be displayed in the LCD and an alarm
will sound. To reset all ERROR displays, press ENTER (Fig. 5C).
B. All normal functions will be disabled when the system is in error mode.
C. Auto level can only commence if running voltage is 12.75V DC or above.
D. Auto level operation will halt if running voltage drops to 9.5V DC.
E.
Manual level operation can be performed at all running voltages above 9.5V DC.

Excess Slope

A. The control will not operate at extreme slopes, i.e. 3.5° fore and aft and 3.5° side to side.
B. If the coach indicates "EXCESS ANGLE" or "OUT OF STROKE " during an auto level cycle, move the
coach to a more level spot .
LCD Display
****ERROR****
Excess Angle
****ERROR****
External Sensor
Out of Stroke
Low Voltage
Function Aborted
Unable to Finish
Leveling
Engage Park Brake
Comm Error
Check Wiring
NOTE: Screen will
not back light.
****ERROR****
Retract Timeout
Return Levelers for
Service
Excessive Angle
Rev: 12.27.2017
What is Happening?
Coach not parked on
level ground.
Zero point incorrectly
calibrated.
Rear sensor shorted out
or disconnected.
Jack has insufficient
length to complete the
leveling procedure.
Battery voltage dropped
below 9.5V DC during
operation.
A button was pressed on
touch pad during Auto
Level operation.
Excessive movement
inside coach during auto
level sequence.
Parking brake not set
prior to starting auto level
sequence.
Wiring connections loose
or faulty between touch
pad and controller.
Pressure switch did not
sense retract pressure
and pump timed out.
Leaking hose or fitting.
Occurs only in manual
mode when the angle of
the unit is too severe.
Page 10
What Should Be Done?
Move coach to level ground
prior to starting auto level
sequence.
Recalibrate Zero Point.
Check wire connection or
replace sensor.
Check the disposition of the
jack.
Turn engine on, check battery
voltage under load.
Hit enter to acknowledge.
Restart procedure.
Discontinue movement
inside coach during auto level
sequence.
Set parking brake prior to
starting auto level sequence.
Check connections, replace
communication harness if
necessary.
Return levelers for service.
Check for leaks, repair if
necessary. Press enter and
retract to clear error.
Use the manual functions to
return coach to a more level
condition.