Failure - Protective Enclosure Open
Failure
Protective enclosure open.
If the protective enclosure is opened during the cycle, the following information will be displayed:
The machine interrupts the working cycle and the band saw head travels in the upper position. Eliminate the failure and close the
protective enclosure. Press F4 (OK) or Enter. If the failure is eliminated, the following information will be displayed:
If "Failure! Protective enclosure open." is displayed after the hydraulic unit has been started, eliminate the failure and close the
protective enclosure. Press F4 (OK) or Enter. If the failure is eliminated, the following information will be displayed:
Failure - Reserve Battery Flat
Failure
Reserve battery is flat
If the reserve battery is flat, the following information will be displayed:
Failure - Thermal Protection of Motor FQ2 (D-NC)
Failure
Thermal protection of motor FQ2
Failure!
Thermal protection of motor
FQ2
Possible Failure Reason
• Protective enclosure open.
• Defective BP6 limit switch.
• Limit switch line is damaged.
System
Failure!
Protective enclosure open.
System
PERFORMING
3pcs
10pcs
pcs:
Time
00:01:15
0 - STOP
9 0
m/min
1 START
2 Kerf
3 Setting
4 Move to initial position
Possible Failure Reason
• Under ideal conditions, the life of the
reserve battery is 7 years.
System
Failure!
Reserve battery is flat!
Possible Failure Reason
• Saw blade motor overload
Possible reasons:
• Descending speed of band saw head in
cutting position is too fast.
• Saw blade is blunt, and/or inappropriate.
The machine interrupts the working cycle and the band saw
head travels in the upper position. Press FQ2 (in main
switchboard) to switch over from 0 to I.
Press Enter; if the failure is eliminated, the following information
will be displayed:
System
Failure!
Protective enclosure open.
-Close protective enclosure
and press OK (F4).
Check BP6 limit switch
System
SERIES: 5
PERFORMING
NO.OF PIECES: 10
LENGTH:
15,0 mm
00:07:28
SERIES: 00:03:45
F4 - STOP
F5 - SERIES
MAIN MENU
System
Failure!
Reserve battery is flat!
Battery: Type CR 2450N - 3V
Failure Elimination
• Close protective enclosure.
• Replace limit switch.
• Check the switch line.
OK
4
20
32
m/min
Failure Elimination
• Replace reserve battery.
Type: CR 2450N - 3V
OK
4
Failure Elimination
• Press control valve to reduce
the descending speed in cutting position.
• Replace saw blade.