Error Messages - Pilous ARG 220 D Instruction Manual

Nc automat
Table of Contents

Advertisement

8. Error Messages

Failure of Moving Vice Feed - Induction sensors IS1, IS2
Failure
Feed failure, Induction sensor
IS1, IS2
System
Failure!
Failure of moving vice
feed (sensor IS1)
After failure elimination press
System
Failure!
OK
Failure of moving vice
feed (sensor IS1)
After failure elimination press
Possible Failure Reason
• Insufficient feed track lubrication.
• Defective limit switch.
• Limit switch line damaged.
IS1 Induction sensor
The LED-diode mus t glow in the limit position of the moving vice.
If this is not the case, adjust the X distance.
Setting: Loosen nut 1 • shorten distance X with nut 2, so that the IS1
Induction sensor diode lights up • tighten nut 1.
IS2 Induction sensor
The LED-diode mus t glow in the limit position of the moving vice.
IS3 Induction sensor
Serves for deceleration of the moving vice in limit positions.
4
Failure Elimination
• Check the track, lubricate the guide bars
• Check the switch function.
• Check the switch line.
IS3
IS1
Lub rica tion s poi nts
INDUCTION SWITCH IS3
SETTING SCREW
Deceleration of moving stop
INDUCTION SWITCH IS2
IS3
IS1
IS3 INDUCTION SWITCH
SETTING SCREW
Deceleration in basic position
LED diode
SETTING SCREW
WITH NUT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents