5. Reverse the DIMMs between the channels (of the same processor), and then restart the server. If the
problem is related to a DIMM, replace the failing DIMM.
6. Re-enable all DIMMs using the Setup utility, and then restart the server.
7. (Trained technician only) Install the failing DIMM into a DIMM connector for processor 2 (if installed) to
verify that the problem is not the processor or the DIMM connector.
8. (Trained technician only) Replace the system board.
A Lenovo optional device that was just installed does not work.
1. Make sure that:
• The device is supported for the server (see http://www.lenovo.com/serverproven/).
• You followed the installation instructions that came with the device and the device is installed
correctly.
• You have not loosened any other installed devices or cables.
• You updated the configuration information in system setup. When you start a server and press F1 to
display the system setup interface. Whenever memory or any other device is changed, you must
update the configuration.
2. Reseat the device that you just installed.
3. Replace the device that you just installed.
114