No. 04: Store_Actual_Parameters - Siemens SIMATIC ET 200SP Manual

As-interface master cm as-i master st 3rk7137-6sa00-0bc1
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

9.4.5

No. 04: Store_Actual_Parameters

Meaning
This command overwrites the configured parameters stored in the EEPROM with the current
ACTUAL parameters stored in volatile memory of the AS-i slave. As a result, the ACTUAL
parameters in the non-volatile memory of the master are stored as the configuration
definition for the next time the slaves are powered up.
The AS-i master parameterizes the AS-i slaves itself in the case of AS-i slaves that meet
AS-i slave standard profile 7.4. The configured parameters for these AS-i slaves are always
equal to F
Structure of the job data in the send buffer
Table 9- 14
Structure of the job data in the send buffer
Byte
0
AS-Interface master CM AS-i Master ST (3RK7137-6SA00-0BC1)
Manual, 07/2017, A5E02655262020A/RS-AD/004
.
H
Command number: 04
9.4 Description of the AS-i commands
Meaning
H
Using the command interface
111

Advertisement

Table of Contents
loading

Table of Contents