14.5 BIOS setup
14.5.2

BIOS setup default settings

Special default settings Panel PC 577
The default settings of the BIOS setup may reset in some circumstances, for example, when
the back-up battery is exchanged or when the BIOS is updated.
If your device has a BIOS version that is older than V5.00 R2.15, the BIOS setup default
settings will not correspond to the default settings of the device. The differences are shown
in the following table and must be entered manually.
Notice
BIOS version older than V5.00 R2.15.1562.01.CB01
If the BIOS has been reset, enter the default settings of the SIMATIC Panel PC 577 listed
below.
System parameters
Main
Floppy disk A
Boot options
POST errors
Advanced
Advanced/peripheral configuration
Diskette controller
Advanced/peripheral configuration/ATA controller config
S-ATA interface
Advanced/system management
SM fan control
Power
APM power saving
Standby timeout
Hard disk timeout
Power/Power On/Off
Power failure recovery
Note
BIOS update
If your device has a BIOS version older than V5.00 R2.15.1562.01.CB01, we recommend a
BIOS update. Further information about this can be found under the item ID 22344494 on
our Support pages.
14-8
BIOS setup
default settings
1.44 MB 3 1/2''
Halt on all errors
Enabled
Enabled
Auto
Customized
15 min
15 min
Previous state
Operating Instructions, Release 04/2006, A5E00798484-01
Default settings
SIMATIC Panel PC 577
None
No halt on any errors
Disabled
Disabled
Enhanced cooling
Disabled
Disabled
Disabled
Always ON