Accupixel Series Camera Customer And Serial Commands; Table 6 Auto Level Control Commands (Optional-Op1-5) - JAI TM-9730CL User Manual

Tm-9730cl series digital monochrome/color progressive scan, interline-transfer cl camera
Table of Contents

Advertisement

9

AccuPiXEL Series Camera Customer and Serial Commands

The AccuPiXEL series cameras can be controlled by serial command either by means of RS-232 or
Camera Link. The Start character is always ":" and the End character is always <CR> (return). For
example, to set Asynchronous Pulse Width Mode, send the command :SA9<CR> to the camera. The
following table contains serial commands that can be used to control the camera.
Table 6
Command
Description
:ALC0<cr>
Disable Auto Level Control
:ALC1<cr>
Enable Auto Level Control
:ALC?<cr>
Enquire Status of
Auto Level Control
:G0=[xx]<cr>
Set Default Gain for
ALC:xx=H100H1FF
:G0?<cr>
Enquire Default Gain for ALC
K1=[xx]<cr>
Set Tuning Factor K1:H100-
H1FF
:K1?<cr>
Enquire Tuning Factor
:X0=[xx]<cr>
Set Desired Level of
ALC:xx=H100-H1FF
:X0?<cr>
Enquire Desired Level of ALC
:STF<cr>
Save user tuning factors
:LTF<cr>
Load user tuning factors
:LTF0<cr>
Load factory default tuning
factors
:LOG0<cr>
Set to linear average detection
for ALC
:LOG1<cr>
Set to Log average detection
for ALC
:LOG?<cr>
Enquire if current user is
linear or log
TM/TMC/RM/RMC-9730CL
Auto Level Control Commands (Optional-OP1-5)
Customer & Serial Commands
Response
:<ack><cr>
:<ack><cr>
:<ack>ALC[x]<cr>
:<ack><cr>
:<ack>G0=[xx]<cr>
:<ack><cr>
:<ack>K1=[xx]<cr>
:<ack><cr>
:<ack>X0=[xx]<cr>
:<ack><cr>
:<ack><cr>
:<ack><cr>
:<ack><cr>
:<ack><cr>
:<ack>LOG[x]<cr>
Comments
x=0 (disabled)
1 (enabled)
If xx is too high or too low ALC
may be unstable.
xx=H100-H1FF
Value must compromise both
response time and stability of
ALC performance
xx= H100-H1FF
If xx is too high or too low ALC
may be unstable
xx=H100-H1FF
X=0 (linear)
1 (log)
37