INSTALLATION AND OPERATION
3. Floating Point
4. Trigger String
2-51 .
Suffixes arc always one or two alpha-characters. Certain suffixes are used to scale the
numeric (the same as the front panel UNITS keys). Other suffixes mnemonically
designate hardware components. The five types of suffixes are described in Table 2-1 1 .
2-52.
The following paragraphs describe the remote IEEE-488 Interface operating commands
that are not accessible from the front panel of the Generator. IEEE-488 Interface
commands that are accessible from the front panel of the Generator are described earlier
in this section.
2- 44
The floating-point numeric data format is the most flexible format. Digits may
be the numerals 0 through 9. Any number of digits are accepted for both the
number and the exponent. However, numbers greater than 2,147,483,629 are
truncated, and exponents greater than 32,749 are rejected.
The trigger string numeric data is a string of Generator commands terminated
with an EOR. The string may be up to 7 1 characters not including the EOR.
Commands in the string are not checked for validity until the trigger string is
executed with the trigger command.
EO R is the end of record character. This character is selectable with the
terminator mode command. "TMO" selects the linefeed character. "TM 1 "
selects the carriage return character. The I EEE-488 interface signal EO!
asserted with any other character is also considered an end of record.
EOS is an end of string character, use either H;" or 4\"'.
command
SUFFIX SYNTAX
Command Descriptions