Sign In
Upload
Manuals
Brands
Fluke Manuals
Inverter
6060B
Fluke 6060B Manuals
Manuals and User Guides for Fluke 6060B. We have
2
Fluke 6060B manuals available for free PDF download: Instruction Manual
Fluke 6060B Instruction Manual (313 pages)
Synthesized RF Signal Generator
Brand:
Fluke
| Category:
Inverter
| Size: 8.8 MB
Table of Contents
Table of Contents
2
Title Page
3
List of Tables
7
List of Illustrations
9
6060B Synthesized Signal Generator
10
Introduction
11
Safety
11
Unpacking the Generator
11
Amplitude
12
Generator Description
12
Controller Functions
12
Frequency
12
Modulation
12
Operator Information Card
12
Reference
12
Amplitude
13
Modulation
13
Reference
13
Remote-Control Programming
13
Mnemonics
14
Options and Accessories
14
Recommended Test Equipment
14
Signal Generator Specifications
14
SIGNAL Generator SPECIFICATIONS
15
Introduction
15
Installation and Operation
22
Initial Inspection
22
Line Power Requirements
22
Setting up the Generator
22
IEEE-488 Address
23
Rack or Bench Mounting the Generator
23
Familiarization
24
General Operating Information
24
Power-On Sequence
24
Changing Output Parameters
24
6060B Outside Dimensions
25
Front Panel Controls, Indicators and Connectors
26
3, Function Entry
30
Bright-Digit Edit Operation
32
Step Operation
32
Memory
33
Modulation On/Off and Rate
33
RF Output On/Off
33
Special Function
34
Operating Reference Material
34
Amplitude and Frequency Entry
34
Amplitude Units Conversion
38
Bright-Digit Edit Entry
38
Memory Entry
40
Modulation Entry
41
Relative Function
43
RF Output On/Off Entry
44
Special Function Entry
45
Status and Clear Entry
45
Step Entry
47
Remote Operation
48
Setting up the IEEE-488 Interface
49
Memory Entry
50
Programming Commands
50
Programming Examples
50
Level Control
53
Entry
54
Modulation Entry
54
Special Function Entry
55
Step Entry
56
Ieee488
57
Programming
57
Commands
58
Programming Examples
58
Interface Functions
59
Address Mode
59
Going from Remote to Local
62
Talk-Only Mode
62
Listen-Only Mode
63
Command Syntax
63
Command Header Syntax
64
Numeric Data Syntax
64
Suffix Syntax
65
Command Descriptions
65
Binary Learn Commands
66
Suffix Types
66
Clear Command
74
Interrogate Commands
76
Monitor Commands
78
SRQ Commands
78
Trigger Commands
78
Command Syntax
80
Command Processing
81
Command Execution
81
Error Handling
81
Timing Data
82
Transfer of Commands to Generator
82
Command-Parsing Time
82
Software Programming Time
82
Timing Optimization
83
Power-On Conditions
84
Theory of Operation
85
General Description
85
Front Section
85
Module Section
85
Introduction
85
Rear Section
85
Functional Description
85
Functional Description
86
Level
86
Amplitude Modulation
86
Frequency Modulation
87
Software Operation
87
User Interface
88
Amplitude Control
88
Attenuators
88
Level DAC
88
Frequency Reference Control
89
Temperature Compensation
89
Modulation On/Off
89
Reverse Power Protector
89
FM Deviation
90
Self Test
90
Amplitude Modulation
90
Frequency Modulation
90
Service Special Functions
91
Status Signals
91
Detailed Circuit Descriptions
92
Data Communications
93
Display Filament Voltage
93
Bright Effect
93
Display Blanking
93
Synthesizer PCA
94
10 Mhz Reference
94
Main Phase-Lock Loop
94
Binary Divider and Single-Sideband Mixer
95
N-Divider
95
Triple-Modulus Prescaler Operation
96
N-Divider Operation
97
N-Divider Timing Diagram
99
Phase Detector
100
Loop Amplifier
100
FM Processing
100
800/40 Mhz PLL
101
800-Mhz VCO
101
Sub-Synthesizer
102
Vco Pca
102
Output PCA
103
RF Path
103
Leveling Loop
104
Modulation Oscillator
106
FM Deviation Control
106
Attenuator/Rpp
106
Controller PCA
107
Microprocessor
107
Attenuator Control Interface
107
Module I/O
108
Reset
108
Status and Control
109
Rear Section
109
Power Supply
109
Suub-Harmonic Reference
110
Non Volatile Memory
110
Power Circuit
110
Memory Control
110
Maintenance
111
Fluke Service
111
Module Replacement
111
Parts Replacement
111
Performance Tests
113
Test Equipment
113
Power-On Test
115
Synthesis Test
115
High-Level Accuracy Test
116
MID-Level Accuracy Test
118
Low-Level Accuracy Test
119
Alternate-Level Accuracy Test
120
Output Linkage Test
121
Alternate Output Leakage Test
122
Harmonic and Spurious Test
123
Modulation Tests
124
AM Depth Range
127
Access Procedures
130
Location of Major Assemblies
130
Access Instructions
130
Removing the Front Section Assembly
130
Removing the Rear Section Assembly
131
Removing the Synthesizer Board
131
Removing the Output Board
131
Removing the Attenuator/Rpp A2A5 Assembly
131
Calibration Adjustments
133
Display Assembly, A1A1
134
Power Supply Test Points
135
Output Assembly, A2A4 Adjustment
136
Module Plate, Botom View
137
Troubleshooting and Repair
149
BBB Field Test Results
155
CCC Field Test Results
155
DDD Field Test Results
155
Check Output Signal
156
Check Power Supply Voltages
157
Power Supply Characteristics
157
Digital and Control Troubleshooting
158
Control Activity
158
Latch Control
158
Power Reset
159
Microprocessor Inputs
159
IEEE-498 Interrupt
159
Address Decoder
159
Address Codes for the Front Panel Keys
160
Synthesizer Troubleshooting
161
Reference Circuitry Check
161
Main Phase Lock Loop
161
Synthesizer PCA Test Points
162
Sub-Synthesizer and HET
164
FM Circuitry
164
Attenuator Level Control
165
Attenuator Check
165
Output RCA Test Points
166
Unleveled Condition
167
AM Troubleshooting
168
Internal/External am
168
ALC Loop Control Voltage
169
Detector Linearity
169
RPP Control
169
List of Replaceable Parts
171
Parts List Information
172
How to Obtain Parts
172
Recommended Spare Parts Kit
173
Options
201
High-Stability Reference
203
Operation
203
Circuit Description
203
Voltage Adjustment
204
Frequency Adjustment
204
Medium-Stability Reference
207
IEEE-488 Interface
210
Low-Rate FM
212
General Information
217
List of Abbreviation and Symbols
218
Manual Change
227
Schematic Diagrams
229
Advertisement
Fluke 6060B Instruction Manual (312 pages)
SYNTHESIZED RF SIGNAL GENERATOR
Brand:
Fluke
| Category:
Inverter
| Size: 30.74 MB
Table of Contents
Instruction Manual
1
Table of Contents
2
L. INTRODUCTION
5
List of Tables
7
Introduction and Specifications
11
Introduction
11
Unpacking the Generator
11
Safety
11
Operator Information Card
12
Generator Description
12
Controller Functions
12
Reference
13
Amplitude
13
Options and Accessories
14
Recommended Test Equipment
14
Mnemonics
14
Signal Generator Specifications
14
Introduction
22
Initial Inspection the
22
Line Power Requirements
22
Line Voltage and Fuse Selection
22
IEEE-488 Address
23
Rack or Bench Mounting the Generator
23
General Operating Information
24
Familiarization
24
L Ocal Versus Remote Operation
24
Power-On Sequence
24
Changing Output Parameters
24
F Ront Panel Controls, Indicators, and Connectors
26
Function Entry
30
Rear Panel Controls, Connectors, and Switches
31
Bright-Digit Edit Operation
32
Step Operation
32
Instrument Preset State
32
Status and Clear Entries
33
2-4 Special Functions
35
Installation and Operation
35
Rf Output On/Off
44
IEEE-488 Commands
52
S Uffi X Types
66
Special Function
71
Interface Mode Commands
74
Input/Output Monitor Commands
79
Read/Write Monitor Commands
80
Command-Parsing Time
82
Frequency Reference Control
89
Calibration Adjustments
133
Introduction
133
2. Safety
133
POWER SUPPLY, A3Al, ADJUST MENT
133
DISPLAY ASSEMBLY, a L AI, ADJUSTMENT PROCEDURE
134
Output Assembly, A2A4, Adjustment
136
I. SYNTHE SIZER ASSEMBLY, A2Al ADJUSTMENT
142
Troubleshooting and Repair
149
Introduction
149
Module Replacement
149
3. Power Supply PCA, A3Al
150
Synthesizer PCA, A2A
150
Vco Pca, A2A2
151
Output PCA, A2A4
151
Display PCA, a L
151
Att Enuatorjrpp PCA A2A5
151
Ieee-488 Pca, A3A3
151
Non-Volatile Memory PCA, A2A8
151
Parts Replacement
151
Troubleshooting
152
Service Special Functions
152
UNCAL Conditions
153
Self Test Description
153
Check Output Signal
156
Auxiliary Power Supply PCA, A3A2
156
Check Power Supply Voltages
157
Control Activity
158
Latch Control
158
Microprocessor Kernel
158
Power Reset
159
Microprocessor Inputs
159
IEEE-488 Interrupt
159
Microprocessor Bus
159
Address Decoder
159
Display and Controls
159
Sub-Synthesizer and HET (800 Mhz), 40-Mhz Loop
164
40. Level Troubleshooting
165
42. Attenuator Level Control
165
Output Assembly Test Point Signal Information
165
Attenuator Check
165
Advertisement
Related Products
Fluke 6062A
Fluke 6060A
Fluke 6060AN
Fluke 6050H
Fluke 6055
Fluke Comark Diligence 600
Fluke 6080AN
Fluke 6070A
Fluke 6071A
Fluke 6080A
Fluke Categories
Measuring Instruments
Test Equipment
Multimeter
Thermometer
Laboratory Equipment
More Fluke Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL