Fluke 6060B Instruction Manual page 62

Synthesized rf signal generator
Hide thumbs Also See for 6060B:
Table of Contents

Advertisement

I
I
I
MESSAGE
soc
I
Sel@cted Device
Clear
Clear
I
Operati on
I
GET
Group Execute
I
Trigger
Trigger
Operati on
I
I
Undef ined IEEE-488
Commands
I
REMOTE OPERATION
2-44.
When in the remote mode, the following conditions are present:
I
The front panel REM indicator is lit.
Device trigger (GET), device clear (DCL), and selected device clear (SDC) interface
messages are processed.
I
All device-dependent messages are processed during the remote mode.
I
2 -45.
GOING FROM REMOTE TO LOCAL
The Generator switches from remote to local mode in one of the following ways: The
IEEE-488 Go To Local (GTL) message is received, the remote enable signal REN is false,
or a Return To Local (rtl) message is generated by pressing the front panel [CLR/ LCL]
I
key (if the Generator is not in the local lockout mode).
The Generator enters the local lockout mode when the Local Lockout message (LLO) is
I
received. The Generator exits the local lockout mode to the local mode when REN is
false.
When switching from remote to local, unprocessed commands in the input buffer are
I
processed until the input buffer is cleared or a front panel entry is made. Switching to
local has no effect on the contents of the output buffer.
I
Talk-Only Mode
2-46.
Figure 2-6 shows two 6060B connected together with the IEEE-488 Bus.
Table 2·10. I EEE-488 Address Mode Message Descriptions (coni)
The S D C message i s i gnored during l ocal ope ration�
Wh@n th@ S D C message i s received ( d u r i ng remote
ope r a t i on > � the Generator i s c l eared. Any characters i n
the i nput buffer are c l eared foL Lowed by the same
o perati on as t h e- c l e a r command ( " CL" ) . The ope r a t i on of the
SDC message i s i denti � a l to the operation of the
c l ea r < D CL) message. The clea red state
i s descrioed in the paragraphs on Power-On Condi t i ons.
The G E T message i s ignored dur i ng Loca L operation. When
the GET message i s received (during remote operati on) ,
the Generator executes
of the G
preprograrnmed w i t h the Conf igure Trigger command ( " CT") .
The operation
operation o f t h e Trigger ("TR") command.
ef
d IEEC-488
A l l und
i n
Gene rator handshake sequence, but no acti on i s taken
INSTALLATION AND OPERATION
DESCRIPTION
of
the Generator
a
command s t r i ng that has b@en
E
T message i s identi cal to t h e
commands a r e a c knowledged by the
dev i ce
2-41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents