Fluke 6060B Instruction Manual page 129

Synthesized rf signal generator
Hide thumbs Also See for 6060B:
Table of Contents

Advertisement

I
g. Verify that the Modulation Analyzer reading is less than 44-Hz rms (or
I
h. Verify that the Modulation Analyzer reading is less than 22-Hz rms (or
I
I.
I
SWR TESTS
4A-13.
These tests use a VSWR bridge and a Spectrum Analyzer to verify SWR of the UUT.
I
REQUIREMENTS
The output VSWR is less than 1.5:
TEST EQUIPMENT REQUIRED
SWR bridge (Wiltron 62N50 or equivalent) High-Frequency Spectrum Analyzer
I
HFSSG (Fluke 6060B or equivalent)
REMARKS
I
The UUT settings in this procedure are chosen to provide confidence in the SWR
performance of the UUT throughout its range. However, performance also may be
checked at other levels <-10 dBm.
I
PROCEDURE
a. Connect the HFSSG to the VSWR Bridge RF IN.
I
b. Connect the Spectrum Analyzer to the VSWR Bridge RF OUT.
I
c. Connect the UUT to the VSWR Device Under Test.
d. Program UUT to 1 M Hz,
I
e. Program the HFSSG to 10 MHz, 13 dBm.
f.
Set the Spectrum Analyzer controls to display approximately 10 to 520 MHz.
I
Set Reference Level to
g. Step HFSSG from 10 MHz to 1050 MHz in 5 MHz-steps and note frequency
I
and level where the level is a maximum.
h. Program HFSSG to the frequency found in step g.
I
I.
Disconnect UUT from VSWR bridge.
j.
Note Spectrum Analyzer level.
I
k. The difference between the levels in steps i and g should be greater than 18 dB.
I.
I
Repeat step
m. The difference between levels in step i and g should be greater than 9.5dB.
I
40-Hz average) at the UUT frequencies listed in step e.
20-Hz average) at the UUT frequencies listed in step d.
Verify that the Modulation Analyzer reading is less than 44-Hz rms (or
40-Hz average) at the UUT frequencies listed in step c.
for output levels <
I
+
1dBm.
10 dBm.
+
e
through k with UUT set to 1 MHz,
ldBm; < 2.0 elsewhere .
+
1 3dBm.
+
MAINTENANCE
PERFORMANCE TISSTS
4A-1 7 /4A-18

Hide quick links: