11. OPERATIONS

11.1 Normal Operation

Power on
When power is applied to the LX505, the Red LED is lit.
Registered card reading
When a registered card (or a PIN) is read (and his/her password is verified), the Door
(Relay#1) will open for 3 seconds (Default) with the Green LED on.
Exit Button
When the Exit button is pressed, the Door (Relay#1) will open for 3 seconds with the
Green LED on.
Alarms
When an unregistered card is read or his/her password is not verified, the access is
denied and the Alarm (Relay#2) will be activated for 3 seconds with the Yellow LED on.

11.2 Default Setting

When you operate the system for the first time or the system has been initialized, the factory
setting values (i.e. the default settings) will be stored in the memory. You can change the
settings for the desired application.