Advertisement

K5305-5PRV2 10/03 Rev. A
REA DY
ARM ED
R
3
STA Y
2
AWA Y
1
OFF
A
BYPA SS
6
5
TEST
4
MAX
B
CHIM E
9
COD E
8
INST ANT
7
C
#
0
REA DY
D
ARM ED
REA DY
OFF
ON
AW AY
1
OFF
2
AWA Y
ST AY
4
MAX
5
TEST
7
INST ANT
8
COD E
PA GE
REA DY
0
F A 5 6 0
)$&36
6
H
F
X
U
L
6
H
F
X
U
3URJUDPPLQJ*XLGH
R
3
STAY
6
BYP ASS
9
CHIM E
#
)$&3
W
\

6
\
V
W
H
L
W
\

6
\
V
W
H







P
V

P
V

Advertisement

Table of Contents
loading

Summary of Contents for First Alert FA168CPS

  • Page 1 )$&36 )$&3 3URJUDPPLQJ*XLGH REA DY ARM ED STA Y AWA Y BYPA SS TEST CHIM E COD E INST ANT REA DY ARM ED REA DY AW AY AWA Y STAY ST AY TEST BYP ASS INST ANT COD E CHIM E PA GE REA DY...
  • Page 2 TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad terminals on the control. A. POWER UP, then depress [ ✱ ] and [#] both at once, within 50 seconds of powering up (if ✱ 98 was used to exit program mode, this method must be used to reenter program mode).
  • Page 3 352*5$00,1*)250 Entries apply to both the FA168CPS and FA148CP controls, except entries shown in dashed boxes, which apply only to the FA168CPS (partition entries) and are not applicable to the FA148CP . Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
  • Page 4 See box above. Use Scheduling mode to set periodic test reports, or use the following key commands: Each mode sets schedule 32 (FA168CPS) or installer code +[#] + [0] + 0 = test report sent every 24 hours schedule 08 (FA148CP) to the stated installer code +[#] + [0] + 1 = test report sent once per week repeat option;...
  • Page 5 ✱ 65 OPEN REPORT CODE [0,0,0] See box above. Part. 1 Part. 2 Common ✱ 66 ARM AWAY/STAY RPT CODE [0,0,0,0,0,0] See box above. Away Stay Away Stay Away Stay Part. 1 Part. 2 Common ✱ 67 RF XMTR LOW BAT REPORT CODE [00] See box on previous page.
  • Page 6 ✱ 92 Entry 1:: 0 = disabled, 1-15 = 1 min - 15 min PHONE LINE MONITOR ENABLE [0,0] (#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; #+13 = 13 min; #+14 = 14 min; #+15 = 15 min) UL: see Inst.
  • Page 7 96 seconds. See Inst. Instr. for explanation. ✱ 198 DISPLAY PARTITION NUMBER 0 = no; 1 = yes (partition no. appears on Alpha Display) (FA168CPS; for Alpha Display Keypads) ✱ 199 ECP FAIL DISPLAY 0 = 3-digit display (“1” + device address) 1 = 2-digit fixed-display as “91”...
  • Page 8 Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182-*185. Configurable zone types 92 and 93 (FA168CPS only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below.
  • Page 9 *56 ZONE PROGRAMMING WORKSHEET (FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets] Zone Zn Type Part. Report Hardwire Rsp. Time Location Type [09] [EOL] [01] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL] [03] [EOL]...
  • Page 10 OUTPUT RELAYS/POWERLINE CARRIER (X-10) DEVICES WORKSHEET FOR ∗79, ∗80 and ∗81. Applicable only if Relays and/or Powerline Carrier Devices are to be used. ∗79 RELAY/POWERLINE CARRIER (X-10) DEVICE MAPPING (Must program before using *80) OUTPUT TYPE OUTPUT TYPE (09-16 apply to FA168CPS only) Relay Relay Output...
  • Page 11 Zone No. By Zone List By Zone No. Number 1 = close 2 secs 0=delete (ZL) (ZT) (ZN) (FA168CPS: 00=none (if using ZT trig) 2 = stay closed FA168CPS: R = relay 1=zn list 1-8 = list (see table 0 = restore...
  • Page 12: Zone Type Definitions

    Zone Type Definitions Type 00 Use this zone type if the zone is not used. Zone Not Used • Assign to zones that are used for primary entry and exit. Type 01 • Provides entry delay if the control is armed in the Away or Stay modes. Entry/Exit Burglary #1 •...
  • Page 13 *The system can still be armed when these zone types are in a faulted condition. Schedules (installer code + [#] + [6] [4]; master code can only access schedules 01-16 for FA168CPS, 01-04 for FA148CP, and events 00-07 for both controls; FA148CP supports up to 8 schedules, FA168CPS supports up to 32 schedules ) Event Device No.
  • Page 14 ALPHA VOCABULARY LIST (For Entering Zone Descriptors) • 057 DOOR ∗ (Word Space) L – • 156 REAR – W – • 106 LAUNDRY ∗ RECREATION WALL • 059 DOWN – A – REFRIGERATION WAREHOUSE • 060 DOWNSTAIRS • 107 LEFT •...
  • Page 15 5800TM Module automatic ** These module addresses apply to FA168CPS only. †† Addressable devices are identified by “1” plus the device address when reporting. Enter report code for zone 91 to enable addressable device reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.
  • Page 16 149 Eileen Way, Syosset, NY 11791 www.firstalertpro.com Copyright © 2003 Honeywell International Inc. ¬.3594l K5305-5PRV2 10/03 Rev. A...

This manual is also suitable for:

Fa148cp

Table of Contents