Installation and connection
78
Unscrew the screws at the bottom edge of the rear panel and re-
move the panel.
Loosen the hexagonal screws to remove the shipping struts.
Retain the shipping struts. They need to be refitted should the ma-
chine ever need to be moved again.

Water connection

Water pressure (flow pressure) of a minimum 1 bar (100 kPa) / maxi-
mum 10 bar (1000 kPa) is required to guarantee problem free pro-
gram operation.
The machine must be connected to the water supply using the inlet
hoses provided.
Hoses must be replaced with hoses tested for a burst pressure of at
least 70 bar (7,000 kPa) overpressure and for water temperatures of a
minimum of 194 °F / 90 °C.
This also applies for associated connection fittings. Miele original re-
placement parts fulfil these requirements.
Tip: The hot water supply must not exceed a maximum temperature
of 158 °F / 70 °C.

Connection to the cold water supply

The Y-piece is supplied with the machine.