Sirona Heliodent Plus Operating Instructions Manual

Sirona Heliodent Plus Operating Instructions Manual

X-ray system
Hide thumbs Also See for Heliodent Plus:
Table of Contents

Advertisement

kÉï=~ë=çÑW==
ebiflabkq
léÉê~íáåÖ=fåëíêìÅíáçåë
008
.
S
7mA DC
7mA DC
MRKOMNN
mirp
Cover page
70kV 60kV
båÖäáëÜ

Advertisement

Table of Contents
loading

Summary of Contents for Sirona Heliodent Plus

  • Page 1 MRKOMNN kÉï=~ë=çÑW== mirp ebiflabkq léÉê~íáåÖ=fåëíêìÅíáçåë båÖäáëÜ Cover page 7mA DC 7mA DC 70kV 60kV...
  • Page 3: Table Of Contents

    Sirona Dental Systems GmbH PLUS Operating Instructions HELIODENT Table of contents General data......................Preface ......................Contact information ..................Intended use....................1.3.1 Indication and contraindication............Structure of the document ................1.4.1 Identification of danger levels............1.4.2 Formats and symbols used ...............
  • Page 4 Sirona Dental Systems GmbH PLUS Operating Instructions HELIODENT 4.6.3 Pre-programmed exposure times for films of sensitivity class E and with a 300 mm (12") FHA cone ............4.6.4 Pre-programmed exposure times with XIOS and XIOS Plus sensors and a 200 mm (8") FHA cone ............
  • Page 5: General Data

    7:30 a.m. to 5:30 p.m. CET. Outside of these times, please contact us via fax. Phone: +49 (0) 6251/16-1670 Fax: +49 (0) 6251/16-1818 Or use our online contact form at www.sirona.com. In the navigation bar, "CONTACT" "Customer Service Center" go to the menu commands "CONTACT FORM FOR TECHNICAL QUESTIONS"...
  • Page 6: Intended Use

    With room temperatures > 35°C (> 95°F) Sirona recommends the use of an air conditioning system. Recommended operating temperature: 18 °C - 35 °C (64 °F - 95 °F)
  • Page 7: Structure Of The Document

    Sirona Dental Systems GmbH 1 General data PLUS Operating Instructions HELIODENT 1.4 Structure of the document Structure of the document Structure of the document 1.4.1 Identification of danger levels Identification of danger levels To prevent personal injury and material damage, please observe the warning and safety information provided in this document.
  • Page 8: Safety Information

    The system owner must ensure that all inspections and maintenance events take place. If the system owner fails to fulfill the obligation to have inspections and maintenance work performed or ignores error messages, Sirona Dental Systems GmbH and its authorized dealers cannot assume any liability for resulting damage.
  • Page 9: Hygiene

    Sirona Dental Systems GmbH 2 Safety information PLUS Operating Instructions HELIODENT 2.4 Hygiene Hygiene Hygiene Suitable hygienic measures must be taken to prevent cross contamination among patients, operators and other persons. Before positioning the patient in the unit, you must ensure that ●...
  • Page 10: Technical Description

    3 Technical description Sirona Dental Systems GmbH PLUS 3.1 Technical data Operating Instructions HELIODENT Technical description Technical description Technical data Technical data Technical data AL1.5 WW Nominal voltage: 120V, 200V– 240V Permissible deviation: ± 10% Rated current: At 120 V: 10 A At 200 –...
  • Page 11 Sirona Dental Systems GmbH 3 Technical description PLUS Operating Instructions HELIODENT 3.1 Technical data Class I device Degree of protection against Type B device electric shock: Degree of protection against Ordinary equipment (without protection ingress of water: against ingress of water)
  • Page 12: Diagrams

    3 Technical description Sirona Dental Systems GmbH PLUS 3.2 Diagrams Operating Instructions HELIODENT Diagrams Diagrams Cooling curve of tube housing Joule x10 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 t (min)
  • Page 13: Standards/Approvals

    Sirona Dental Systems GmbH 3 Technical description PLUS Operating Instructions HELIODENT 3.3 Standards/Approvals Standards/Approvals Standards/Approvals CE mark PLUS The HELIODENT complies with the following standards, among others: ● IEC 60601-1 ● IEC 60601-2-28 / 1993 ● IEC 60601-1-3 / 1994 ●...
  • Page 14: Controls And Functional Elements

    4 Controls and functional elements Sirona Dental Systems GmbH PLUS 4.1 Operating and Display Elements Operating Instructions HELIODENT Controls and functional elements Controls and functional elements Operating and Display Elements Operating and Display Elements Main ON/OFF switch Readiness for operation indicator (LED)
  • Page 15: Meaning Of The Icons

    Sirona Dental Systems GmbH 4 Controls and functional elements PLUS Operating Instructions HELIODENT 4.2 Meaning of the icons Meaning of the icons Meaning of the icons Patient symbol Adult Child Plus key Minus key Exposure release button Maxillary front tooth...
  • Page 16: Display Structure

    4 Controls and functional elements Sirona Dental Systems GmbH PLUS 4.3 Display structure Operating Instructions HELIODENT Display structure Display structure The background lighting of the display indicates the current status of the unit. Background color Meaning Blue Ready for radiation...
  • Page 17: Accessories

    Order No. 62 41 983 Square cone extension to 300 mm FHA (12") Order No. 62 41 975 Radiation field limitation blue 3 x 4 cm with rotary handle for Sirona XIOS/ Plus XIOS Size 2 Sensor, Sirona Full Size Sensor and conventional imaging technology Order No.
  • Page 18: Exposure Times

    4 Controls and functional elements Sirona Dental Systems GmbH PLUS 4.6 Exposure times Operating Instructions HELIODENT Exposure times Exposure times 4.6.1 Possible exposure times in seconds Possible exposure times in seconds 0,01 0,02 0,03 0,04 0,05 0,06 0,08 0,10 0,12 0,16 0,20 0,25 0,32 0,40 0,50 0,64 0,80 1,00 1,25 1,60 2,00 2,50 3,20 4.6.2...
  • Page 19: Pre-Programmed Exposure Times For Films Of Sensitivity Class E And With A 300 Mm (12") Fha Cone

    Sirona Dental Systems GmbH 4 Controls and functional elements PLUS Operating Instructions HELIODENT 4.6 Exposure times 4.6.3 Pre-programmed exposure times for films of sensitivity class E and with a 300 mm (12") FHA cone Pre-programmed exposure times for films of sensitivity class E and with a 300 mm (12") FHA cone...
  • Page 20: Pre-Programmed Exposure Times With Xios And Xios Plus Sensors And A 200 Mm (8") Fha Cone

    4 Controls and functional elements Sirona Dental Systems GmbH PLUS 4.6 Exposure times Operating Instructions HELIODENT 4.6.4 Pre-programmed exposure times with XIOS and XIOS Plus sensors and a 200 mm (8") FHA cone Pre-programmed exposure times with XIOS and XIOS Plus sensors and a 200 mm (8") FHA cone...
  • Page 21: Pre-Programmed Exposure Times For Xios And Xios Plus Sensors With A 300 Mm (12") Ssd (Round Or Square Cone)

    Sirona Dental Systems GmbH 4 Controls and functional elements PLUS Operating Instructions HELIODENT 4.6 Exposure times 4.6.5 Pre-programmed exposure times for XIOS and XIOS Plus sensors with a 300 mm (12") SSD (round or square cone) Pre-programmed exposure times for XIOS and XIOS Plus sensors with a 300 mm (12") SSD (round or square cone)
  • Page 22: Operation

    5 Operation Sirona Dental Systems GmbH PLUS 5.1 Preparing the exposure Operating Instructions HELIODENT Operation Operation Preparing the exposure Preparing the exposure 5.1.1 Switch the unit on Switch on the unit with the main switch (A) (Position I). Switch the unit on During this process none of the keys of the operating panel must be pressed.
  • Page 23: Selecting The Patient Symbol

    Sirona Dental Systems GmbH 5 Operation PLUS Operating Instructions HELIODENT 5.1 Preparing the exposure 5.1.3 Selecting the patient symbol Selecting the patient symbol Press the button with the adult patient icon if you wish to take an X-ray of an adult.
  • Page 24: Positioning The Patient/X-Ray Tube Assembly

    ● Position the film or the X-ray sensor using a holding system for the parallel technique. ● For Sirona X-ray sensors, only the holding systems recommended by Sirona may be used. ● Please comply with the operating instructions for intraoral X-rays supplied with the sensors or films.
  • Page 25: Releasing The Exposure

    Sirona Dental Systems GmbH 5 Operation PLUS Operating Instructions HELIODENT 5.3 Releasing the exposure Releasing the exposure Releasing the exposure CAUTION Comply with the radiation protection provisions. NOTICE When using a digital sensor system, establish exposure readiness before you release the exposure.
  • Page 26: Adapting Basic Settings

    5 Operation Sirona Dental Systems GmbH PLUS 5.4 Adapting basic settings Operating Instructions HELIODENT Adapting basic settings Adapting basic settings Exposure times for the use of films with the sensitivity class E are factory Plus pre-set, as well as the XIOS/XIOS sensors.
  • Page 27 Sirona Dental Systems GmbH 5 Operation PLUS Operating Instructions HELIODENT 5.4 Adapting basic settings 4. The base value can now be adjusted by pressing the plus or minus buttons. Each level corresponds to about a 25% extension or reduction in exposure time.
  • Page 28: Maintenance

    ➢ Do NOT use: Substances containing phenol, peracetic acid, peroxide or any other oxygen-splitting agents, sodium hypochlorite or iodine-splitting agents. ➢ Use only cleaning and disinfecting agents approved by Sirona! A continuously updated list of approved agents can be downloaded from the Internet at: "www.sirona.com"...
  • Page 29: Maintenance Of Accessories

    Sirona Dental Systems GmbH 6 Maintenance PLUS Operating Instructions HELIODENT 6.1 Cleaning and care Sirona recommends the following disinfectants: ● MinutenSpray classic, by ALPRO® ● MinutenWipes, by ALPRO® ● In the USA and Canada: ● CaviCide® or ● CaviWipes ™ .
  • Page 30: Inspection And Maintenance

    6 Maintenance Sirona Dental Systems GmbH PLUS 6.2 Inspection and maintenance Operating Instructions HELIODENT Inspection and maintenance Inspection and maintenance Inspection and maintenance Inspection and preventive maintenance must be performed at scheduled intervals to protect the health and safety of patients, users and other persons.
  • Page 31: Error Messages

    Sirona Dental Systems GmbH 7 Error messages PLUS Operating Instructions HELIODENT 7.1 List of error messages Error messages Error messages Errors during the self-test are indicated by a five-digit number lighting up. The background color of the display is red.
  • Page 32 7 Error messages Sirona Dental Systems GmbH PLUS 7.1 List of error messages Operating Instructions HELIODENT Error code Reason and measures E1 04 51 Safety circuit - the door switch may not be closed properly Switch the device OFF and then ON again, check the...
  • Page 33: Disposal

    Disposal of the X-ray tube assembly Disposal of the X-ray tube assembly Heliodent Plus X-ray tube assembly The X-ray tube assembly in this device contains a tube which can implode, a lead lining and mineral oil. 62 14 717 D3507...
  • Page 34: Dose Area Product (Dfp)

    9 Dose area product (DFP) Sirona Dental Systems GmbH PLUS Operating Instructions HELIODENT Dose area product (DFP) Dose area product (DFP) Information on patient exposure Explanation The patient's exposure to radiation can be determined in the tables below. To compensate for measuring errors as well as for system and instrument variations, a tolerance of 20% must be taken into account.
  • Page 35 Sirona Dental Systems GmbH 9 Dose area product (DFP) PLUS Operating Instructions HELIODENT Calculation and definition of the dose area product for the PLUS HELIODENT Tables with typical values for the dose area product (DFP) Dose area product cone 200 WW...
  • Page 36 9 Dose area product (DFP) Sirona Dental Systems GmbH PLUS Operating Instructions HELIODENT Round cone: with radiation field limitation 300 mm (12") 60 kV 70 kV 60 kV 70 kV 60 kV 70 kV Time mGy cm mGy cm mGy cm...
  • Page 37: Brief Operating Instructions

    Brief Operating Instructions Brief Operating Instructions...
  • Page 40 tÉ=êÉëÉêîÉ=íÜÉ=êáÖÜí=íç=ã~âÉ=~åó=~äíÉê~íáçåë=ïÜáÅÜ=ã~ó=ÄÉ=êÉèìáêÉÇ=ÇìÉ=íç=íÉÅÜåáÅ~ä=áãéêçîÉãÉåíëK «=páêçå~=aÉåí~ä=póëíÉãë=dãÄe=OMNN péê~ÅÜÉW ÉåÖäáëÅÜ mêáåíÉÇ=áå=dÉêã~åó aPRMTKOMNKMNKMSKMO MRKOMNN ûKJkêKW= NNQ=NVQ páêçå~=aÉåí~ä=póëíÉãë=dãÄe áå=íÜÉ=rp^W SO=NQ=TNT=aPRMT c~Äêáâëíê~≈É=PN páêçå~=aÉåí~ä=póëíÉãë=ii` lêÇÉê=kç SQSOR=_ÉåëÜÉáã QUPR=páêçå~=aêáîÉI=pìáíÉ=NMM dÉêã~åó `Ü~êäçííÉI=k`=OUOTP ïïïKëáêçå~KÅçã...

Table of Contents