Adjustments and servicing procedures

ADJUSTMENT OF THE CONTINUOUS PNEUMATIC REGULATING SYSTEM
(1)
(2)
The working pressure is determined by the tension of
the spring in the regulating valve (1). This tension can
be increased to raise the pressure and decreased to
lower it by turning the adjusting wheel clockwise and
anti-clockwise respectively.
To adjust the normal working pressure, proceed as
follows:
1. Loosen the lock nut of the regulating valve.
2. Release Regulating Valve (turn out).
3. With the outlet valves (2) closed, adjust the
regulating valve (1), until a pressure is reached of
nominal pressure + 1.5 bar (+ 22 psi).
4. Lock the regulating valve (1) by fixing the lock
nut.