Maintenance schedule (hrs)
(continuation of page 59)
Grease hinges
Analyse coolant (4) (8)
Check/Replace safety cartridge
Check emergency stop
(to be continued on page 61)
Notes
1. More frequently when operating in a dusty environment.
2. Refer to engine operation manual.
3. After a day's work.
4. Yearly is only valid when using PARCOOL. Change coolant every 5 years.
5. Use Atlas Copco oil filters, with by-pass valve as specified in the parts list.
6. Gummed or clogged filters means fuel starvation and reduced engine performance.
7. See section Oil specifications.
8. The following part numbers can be ordered from Atlas Copco to check on inhibitors and freezing
points:
 2913 0028 00 : refractometer
 2913 0029 00 : pH meter.
9. See section Safety valve.
10. See section Before starting.
11. Replace all rubber flexibles every 6 years.
12. For other specific engine and alternator requirements refer to specific manuals.
13. 250 hours is only valid when using PAROIL E or PAROIL E xtra.
Daily
50 hrs
Every
after initial
250 hrs
start-up
- 60 -
Every
Every
Every
500 hrs
750 hrs
1000 hrs
Keep the bolts of the housing, the lifting
eye, the towbar and the axle securely
tightened.
Refer to section Technical specifications
for the torque values.
Every
Yearly
2000 hrs
x
x
x
x