Page 1
Instruction Manual for Portable Compressors English XRXS 567 Cd - XRXS 1240 CD7 XRXS 607 Cd - XRXS 1275 CD7 Engine CAT C18 XRVS 617 Cd - XRVS 1300 CD7 XRVS 647 Cd - XRVS 1350 CD7...
Page 3
Instruction Manual for Portable Compressors XRXS 567 Cd - XRXS 1240 CD7 XRXS 607 Cd - XRXS 1275 CD7 XRVS 617 Cd - XRVS 1300 CD7 XRVS 647 Cd - XRVS 1350 CD7 Printed matter N° ATLAS COPCO - PORTABLE AIR DIVISION 9829 3007 48 www.atlascopco.com...
Page 4
The manufacturer does not accept any liability for any damage arising for modifications, additions or conversions made without the manufacturer's approval in writing. While every effort has been made to ensure that the information in this manual is correct, Atlas Copco does not assume responsibility for possible errors.
Preface Table of contents Starting / Stopping ........30 BATTERY SWITCH......... 30 Please read the following instructions carefully before starting to use your compressor. 5.1.1 Control panel ......... 30 Safety precautions ........7 5.1.2 Operations overview ......33 Introduction ..........7 It is a solid, safe and reliable machine, built 5.1.3 Battery switch ........
Page 6
6.6.2 Check compressor oil level ....61 7.2.1 Priming instructions ....... 72 Disposal ............. 98 7.2.2 Replacing filter elements ....... 73 Oil and oil filter change......62 13.1 General ............98 7.2.3 Cleaning crankcase breather filter ..73 6.7.1 Engine oil and oil filter change ....62 13.2 Disposal of materials........
To be read attentively and acted accordingly before towing, lifting, operating, performing maintenance or repairing the compressor. INTRODUCTION The policy of Atlas Copco is to provide the users of It is the responsibility of management to appoint Take necessary steps to keep unauthorized persons...
The manufacturer does not accept any liability for any GENERAL SAFETY PRECAUTIONS Care shall be taken to avoid damage to safety damage arising from the use of non-original parts and valves other pressure-relief devices, The owner is responsible for maintaining the unit for modifications, additions or conversions made especially to avoid plugging by paint, oil coke or in a safe operating condition.
13 If the warning light on the ABS module or in the residential areas. Lifting acceleration and retardation cable or safety chain. If the unit has no parking vehicle lights up, please contact Atlas Copco. shall be kept within safe limits. brake or jockey wheel, immobilize the unit by...
Page 10
13 Never refill fuel while the unit is running, unless - above 85 dB(A): room to be classified as a next to the valve. otherwise stated in the Atlas Copco Instruction noise-hazardous area and an obvious warning No external force may be exerted on the air outlet Book (AIB).
(check valves) to isolate recommended or approved by Atlas Copco or the pressure systems. In addition, a warning sign machine manufacturer. Ascertain that bearing a legend such as ”work in progress; do selected lubricants comply with all applicable not open”...
15 Protect the engine, alternator, air intake filter, 23 Make sure that oil, solvents and other substances electrical and regulating components, etc., to likely to pollute the environment are properly prevent moisture ingress, e.g. when steam- disposed of. cleaning. 24 Before clearing the unit for use after maintenance 16 When performing any operation involving heat, or overhaul, check that operating pressures, flames or sparks on a machine, the surrounding...
SPECIFIC SAFETY PRECAUTIONS Pressure vessels (Pressure) vessel maintenance is to be performed by Atlas Copco. Maintenance/installation requirements: Batteries The vessel can be used as pressure vessel or as When servicing batteries, always wear protecting separator and is designed to hold compressed air Safety valves clothing and glasses.
The engine’s power is transmitted to the compressor The oil is removed from the air, in the air/oil vessel at The XRXS 567 Cd - XRXS 1240 CD7 and XRXS 607 element through a heavy-duty coupling. first by centrifugal force, secondly through the oil Cd - XRXS 1275 CD7 are silenced, two-stage, oil- separator element.
Page 15
Cooling system Serial number The engine is provided with a liquid-cooler and intercooler and the compressor is provided with an oil cooler. (For available options see chapter Available options.) The cooling air is generated by a fan, driven by the engine.
Page 17
Reference Name Reference Name Reference Name AFce Air Filter (compressor element) Emergency Stop Regulating Pressure Sensor Air Filter (engine) Element Temperature Sensor Regulating Valve Air Filter Switch Serial Number Air Outlet Valves FCeo Filler Cap (engine oil) Safety Valve Air Receiver FCft Filler Cap (fuel tank) Towbar...
AIR FLOW Air drawn through the airfilter (AFce) into the When the compressor is stopped and / or there is no Reference Name compressor element (CElp CEhp) is compressed. At pressure in the system, the oil stop valve (OSV) the element outlet, compressed air and oil pass into prevents the oil from flowing back into the Regulating Pressure Sensor the air receiver/oil separator (AR/OS).
Page 21
The compressor is provided with a pneumatic If the air consumption is less than the maximum air regulating system and a blow-off valve (BOV) which output, air receiver pressure increases and the is integrated in the unloader assembly (UA). The regulating valve supplies control air to throttle valve valve is closed during operation by outlet pressure of (TV) to reduce the air output and holds air receiver...
Read the instruction manual before Read the instruction manual before Electrocution hazard. starting. lifting. Atlas Copco synthetic compressor oil. Service every 24 hours. Filler cap coolant. Read the instruction manual before Atlas Copco mineral engine oil. Warning! Part under pressure.
Operating instructions PARKING INSTRUCTIONS WAGON PARKING, TOWING AND LIFTING INSTRUCTIONS Safety precautions The operator is expected to apply all relevant Safety precautions. Attention Before putting the compressor in to use, check the brake system as described in section Brake adjustments. After the first 100 km travel: Uncouple vehicle.
TOWING INSTRUCTIONS WAGON TOWBAR LEVELLING WAGON LIFTING INSTRUCTIONS The towbar of the wagon is equipped with an To lift the compressor, use a lift truck or crane with Before towing the compressor, ensure adjustable spring loaded levelling device. sufficient capacity (weight: see indication on that the towing equipment of the vehicle Dataplate).
INTERNAL LIGHTING PREHEATER (OPTION) When an emergency stop has to be performed: Before performing any maintenance jobs always switch off the preheater and • Switch off the preheater at the control element remove the fuse or disconnect the heater • Remove the fuse or disconnect the heater from the from the battery.
Page 28
General Setting pre-settings • When no button is pressed the display will return • By pressing button (1) once, twice or three times to its default mode - normal time display. you will select pre-set time 1, 2 or 3. •...
BEFORE STARTING 5. Check the level of the compressor oil. See section Check compressor oil level. The pointer of oil level gauge (OLG) should register in the green range. Add oil if necessary. See section Compressor oil for the oil to be used. Before removing oil filler plug (FP), ensure that the pressure is released by opening an air outlet valve.
Starting / Stopping Safety precautions CONTROL PANEL Do not disconnect power supply to control box in any way when the control box is switched on. This will cause memory loss. Do not switch off the circuit breaker when the control box is switched on. This will cause memory loss.
Page 31
Reference Name POWER OFF / ON switch To switch the control panel on and off START button Pressing this button will start the compressor. STOP button Pressing this button will stop the compressor in a controlled way. LOAD button. Pressing this button will: •...
Page 32
ENTER button Confirms/stores the selection/change. BACK button Moves back one level or ignores the change. - 32 -...
OPERATIONS OVERVIEW BATTERY SWITCH It is possible to control the compressor locally with Regularly carry out following checks: The compressor is equipped with a battery switch. the Control Box, remotely with the remote switch 1. That the regulating valve (RV) is correctly When the compressor is not in use this switch must inputs located on the back of the Control Box, or with adjusted, i.e.
OVERVIEW ICONS Reference Name Compressor status Vessel pressure indication or info text Compressor info Main View Indication Measuring View Indication Settings View Indication MAIN VIEW LOADED Alarm View Indication DPF REGENERATION High Exhaust System Temperature. Means that the Diesel Particle Filter is being regenerated.
Page 35
Reference Name Reference Name Reference Name DPF REGENERATION OPERATION MODE FUELTANK Diesel Particle Filter Regeneration Local Running at internal fueltank. Inhibited. Means that the DPF regeneration is OPERATION MODE FUELTANK inhibited, even if all criteria to Remote Running at internal fueltank & activate a regeneration are met.
STARTING The display now shows Switch on the battery switch. Switch the controller on by switching the Power MAIN VIEW MAIN VIEW switch to the position “ON”. VESSEL BLOWING DOWN PREPARING FOR START The instrument panel will now perform a selftest; the following display will be shown and the controller is initialized: 1286h...
Page 38
The display now shows The display now shows MAIN VIEW MAIN VIEW MAIN VIEW PREPARING FOR START READING ENGINE DATA ENGINE PREHEATING 1286h --RPM 0.0bar 1286h --RPM 0.0bar 1286h --RPM 0.0bar After pressing the START button the machine will The engine electronics (ECU) will be powered up. activate its horn and flasher light for 5 seconds, to Active Buttons As soon as communication between compressor...
Page 39
The engine starts crancking, the display shows The display now shows The engine starts running at idle speed. The display shows MAIN VIEW MAIN VIEW MAIN VIEW ENGINE CRANKING ENGINE RESTING ENGINE WARMING UP 13˚C 40˚C 0RPM 800RPM 120s 25˚C 324RPM 300s 1286h...
Page 40
The display now shows After warming up the machine is ready to be loaded and is waiting for a load command; the display shows MAIN VIEW MAIN VIEW ENGINE WARMING UP READY TO LOAD 1286h 1200RPM 2.9 bar 1286h 1200RPM 4.6bar Active Buttons Active Buttons...
Page 41
Press the load button, the display will show The engine will now run at maximum rpm, the display During loading the following display is shown will show (default display) MAIN VIEW MAIN VIEW MAIN VIEW LOADED BUILDING UP VESSEL PRESSURE PREPARING TO LOAD 18.6 1286h...
Page 42
Set the Pressure/Flow Setpoint Some additional control features are available from When the controller is in the Main View (shift Atlas Copco, such as dual pressure switch, remote The doors must be closed during between PRESSURE and FLOW VIEW with right/ start, auto start, remote pressure setting.
STOPPING REGENERATION. After pressing the STOP button the display will show: MAIN VIEW MAIN VIEW ENGINE COOLING DOWN ENGINE COOLING DOWN 180s 180s Press ENTER to allow DPF regen before stop DPF Soot Load level 50 1286h 1200RPM 19.4bar 1286h 1200RPM 6.0bar After a Stop command, or in case of a controlled stop...
SHUTDOWN POWER OFF After cooling down the engine will stop and the When the machine is shutdown due to a critical alarm Switch the controller off by switching the Power display will show or an emergency stop the display will show switch to the position “OFF”.
AUTOMATIC DPF REGENERATION (DEFAULT) MAIN VIEW In specific cases, when the engine speed is constant at If Enter is pressed within 10 seconds then the LOADED Minimum RPM, it can happen that the DPF controller will allow the DPF regeneration to be regeneration already starts from 30% Soot Load (LSR completed before the engine is stopped.
INHIBIT DPF REGENERATION INCREASING SOOT LOAD When running in an environment where an elevated When the DPF Regeneration is Inhibited, or when the SOOT LOAD reaches 90% (only when DPF exhaust temperature is not allowed, it might be engine does not get sufficient possibility to Regeneration is Inhibited) necessary to inhibit DPF regeneration.
Page 47
Regeneration Needed icon will disappear (engine electronics are powered down). 7110 LOAD PREVENTION - HIGH DPF SOOT LO... Required Action: Contact Atlas Copco for further actions • Acknowledge the ‘ECU DPF SOOT LOAD Required Action: to be taken. HIGH’ warning (press Enter while in the Main •...
FORCE DPF REGENERATION If DPF Regeneration is Inhibited Machine is not running: Power the controller down. At next power up, the DPF Regeneration settings will be back to default, and an Automatic DPF Regeneration will take place at the soonest appropriate moment. Machine is running: •...
SETTINGS For buttons to be used see “Control Panel” As long as there is an alarm icon in the middle of the Set Language bottom part of the view, all active acknowledged / un- Press the SETTINGS VIEW button. Acknowledge an Alarm acknowledged alarms can be seen by pressing the •...
Page 50
Change Display Settings Press the SETTINGS VIEW button • scroll to ‘1000 GENERAL SETTINGS’ • press ENTER • scroll to ‘1310 DISPLAY BACKLIGHT’ • ENTER the DISPLAY BACKLIGHT menu • scroll to the setting you would like to change • press ENTER. To change a setting, the red figure is editable.
FAULT CODES There are several parameters that are continuously When one of these parameters exceeds its specified watched. limit the compressor will react depending the present status of the control box. Alarmcode Alarmtext Failclass Trigger 1231 FUEL FILL CHECK Warning 1503 INITIAL OVERHAUL REQUIRED Warning...
EMERGENCY STOP The emergency stop button is only to be used in emergency situations; not for stopping procedures. When an emergency stop button (1) is pressed, power to all outputs is terminated, by the emergency stop itself (hardware) as well as by the software. When the emergency stop button (1) is pressed the operator can unlock the emergency stop by turning it counterclockwise.
Service Paks minimize downtime and keep your protective measures must be taken. maintenance budget low. Order Service Paks at your local Atlas Copco dealer. - 55 -...
Every 6 months or Yearly or every initial start-up 500 hours 1000 hours XRXS 567 Cd - XRXS 1240 CD7 2912 6075 05 2912 6076 06 XRXS 607 Cd - XRXS 1275 CD7 XRVS 617 Cd - XRVS 1300 CD7...
Page 57
Maintenance schedule Daily 50 hours after Every 6 months or Yearly or every (continuation of page 56) initial start-up 500 hours 1000 hours Radiator Clean Clean Intercooler Clean Clean Torque of wheel nuts Check Check Check Brake system (if installed) Check/Adjust Check/Adjust Check/Adjust...
Page 58
The quality of the fuel determines the frequency of renewal. 8. See section Oil specifications. 9. The following part numbers can be ordered from Atlas Copco to check on inhibitors and freezing point: • 2913 0028 00 refractometer •...
OIL SPECIFICATIONS It is strongly recommended to use Atlas The viscosity grade should correspond to the ambient temperature and ISO 3448, as follows: Copco branded lubrication oils for both Type of lubricant Compressor Engine compressor and engine. between -25°C (-13°F) and +30°C (86°F) PAROIL S PAROIL 5W40 between -10°C (14°F) and +30°C (86°F)
ENGINE OIL PAROIL from Atlas Copco is the ONLY oil tested PAROIL contains high quality anti-oxidants to PAROIL 5W40 is a Synthetic ultra high performance and approved for use in all engines built into Atlas control deposits, sludge and contaminants that tend to diesel engine oil with a high viscosity- index.
OIL LEVEL CHECK CHECK COMPRESSOR OIL LEVEL CHECK ENGINE OIL LEVEL Also consult the Engine Operation Manual for the oil specifications, viscosity recommendations and oil change intervals. For intervals, see Preventive maintenance schedule for the compressor. Check engine oil level according to the instructions in the Engine Operation Manual and if necessary top up with oil.
4. Reinstall and tighten the filler plug (1). schedule for the compressor). When operating in high ambient temperatures, in very dusty or high humidity conditions, it is recommended to change the oil more frequently. In this case, contact Atlas Copco. - 62 -...
COOLANT SPECIFICATIONS 1. Run the compressor until warm. Close the outlet Never remove the cooling system filler valve(s) (3) and stop the compressor. Wait until cap while coolant is hot. the pressure is released through the automatic The system may be under pressure. blow-down valve.
50/50 your health and the environment. Longer service life currently in use in Atlas Copco compressors and dilution ratio, for antifreeze protection guaranteed to reduces the amount of coolant produced and needing generators.
PARCOOL EG is compatible with most other • A refractometer can be ordered from Atlas Copco injury from the splash of hot coolant. coolants based on ethylene glycol, but you only get the benefits of 5 years protection when its used on its with part number 2913 0028 00.
TOPPING UP WITHOUT DRAINING FROM THE COOLING SYSTEM The quantity of PARCOOL EG Concentrate to be topped up can be estimated with the following formula and/or graph: Corrections concentrate in measured system towards 50% volume by using PARCOOL EG Concentrate Example: PN: 1604 8159 00 Total volume coolant =...
TOPPING UP AFTER LIMITED QUANTITY DRAINING FROM THE COOLING SYSTEM The quantity of PARCOOL EG Concentrate to be topped up after draining a calculated volume from the cooling system, can be estimated with the following formula and/ or graph: Corrections concentrate in measured system towards 50% volume by using PARCOOL EG Concentrate Example: PN: 1604 8159 00 Total volume coolant =...
Protect the electrical and controlling and local regulations. equipment, air filters, etc. against penetration of moisture. • From the Atlas Copco Instruction book, determine the amount of PARCOOL EG required and pour Never leave spilled liquids such as fuel, into the radiator top tank.
When a compressor element is due for overhaul, it electrolyte. ELECTROLYTE needs to be done by Atlas Copco. This guarantees the • Refit plugs and/or cover. use of genuine parts and correct tools with care and • Place the battery in the compressor.
Adjustments and servicing procedures Single pressure system ADJUSTMENT OF THE PNEUMATIC REGULATING SYSTEM The working pressure is determined by the tension of the spring in the regulating valve (RV). This tension can be increased to raise the pressure and decreased to lower it by turning the adjusting wheel clockwise and anti-clockwise respectively.
3. Safety cartridge 6. Vacuator valve 4. Inspect and tighten all air intake connections. The Atlas Copco air filters are specially designed for the application. The use of non-genuine air filters may lead to severe damage of the engine and/or compressor elements.
AIR RECEIVER SAFETY VALVE FUEL SYSTEM All adjustments or repairs are to be done PRIMING INSTRUCTIONS by an authorized representative of the safety valve (2) supplier, see section Fuel leaked or spilled onto hot surfaces Specific safety precautions. or electrical components can cause a fire. To help prevent possible injury, turn the “ON/OFF”...
REPLACING FILTER ELEMENTS CLEANING CRANKCASE BREATHER FILTER Replacing the filter elements: Installation instructions: 1. Drain fuel from the bowl. 2. Remove filter (2, 3), filterelement (4) and separate bowl (2) from element (3). 3. Apply film of gas oil to new bowl seat. 4.
MAINTENANCE QUICK ACTION FUEL BRAKE ADJUSTMENTS COUPLINGS BRAKE SHOE ADJUSTMENT WAGON Functional test: Even with proper selection and installation, quick action coupling life may be significantly reduced Operate the system at maximum operating pressure without continuing maintenance program. and check for possible malfunctions and freedom Frequency should be determined by the severity of from leaks.
BRAKE ADJUSTMENT WAGON Adjusting the linkage • The parking brake is adjusted by using the turnbuckle (8). Adjust till the play in the linkage is 1-3 mm (max. 3mm is allowed). • Apply the parking brake lever several times by hand with a force of 200 to 300 N and put it back into the -not engaged- tooth “1”...
Choked air filter elements (AF). Remove and inspect elements. Clean or replace, if necessary. Regulating valve (RV) defective. Have regulating valve removed and inspected by an Atlas Copco Service representative. Blow down valve stuck in open position. Check and correct as necessary.
Page 77
Possible faults Corrective actions Regulating valve (RV) opens too late or its ball valve spring is broken. Have regulating valve removed and inspected by an Atlas Copco Service representative. Air leaks in regulating system. Check hoses and their fittings. Stop leaks; replace leaking hoses.
Page 78
Check and correct if necessary. Oil stop valve malfunctioning. Remove and inspect valve. Oil separator element (OS) clogged. Have element removed and inspected by an Atlas Copco Service representative. Alternator precautions 1. Never reverse the polarity of the battery or the alternator.
Block the valve by screwing a bolt (M5 x 20) through the housing and in the blind hole in the coupling. Possible faults Corrective actions Contact Atlas Copco for a thorough scan Device switched off and on again too many Contact your agent. and repair.
Available options UNDERCARRIAGE SUPPORT MOUNTED / LARGE FUELTANKS SKID / LARGE FUELTANKS The undercarriage makes it possible to move the With the option “Support mounted” it is possible to compressor on the site with a truck to the location fix the compressor to a truck for more flexibility or to where it is needed.
Page 81
WHEEL CHOCKS ADDITIONAL FUELFILTER ELECTRIC REFUEL PUMP For extra safe parking on slopes. In dusty environments or in situations where the fuel The electric refuel pump makes it easy to refuel the quality is not up to the normal standard, this compressor on site when refuelling from tanks or additional fuel filter gives an extra protection to the containers.
Page 82
EXTERNAL FUEL CONNECTION SPARK ARRESTOR PREHEATER When a compressor is operated on site for a longer The certified spark arrestor is an addition to the The preheater is a device for preheating the cooling period it is advisable to supply the fuel through exhaust that makes it possible to operate the fluid before starting when operating at low external fuel connections.
Page 83
COLD WEATHER PACKAGE INLET SHUTDOWN VALVE OILTRONIX The cold start option consists of larger batteries The OILTRONIX is an Electronic Oil Management and a blow off valve to be able to start the engine System for compressors providing an optimal oil at temperatures between -10°C (14°F) and -25°C injection temperature that reduces the condensation (-13°F).
Page 84
REGULATING SYSTEM SINGLE PRESSURE REGULATING SYSTEM DUAL PRESSURE REGULATING SYSTEM DUAL PRESSURE FUEL EXPERT NO FUEL EXPERT FUEL EXPERT This is a control module that regulates engine speed and the air inlet to optimise fuel consumption depending on the working conditions, and the output required.
Page 85
PRESSURE REGULATOR EC PRESSURE REGULATOR ASME FORK LIFT SLOTS With fork lift slots the compressor can easily be moved with a fork lift truck on building sites where it is impossible to use a towing truck. A pressure regulating system according to European A pressure regulating system according to US standards for reducing the operating pressure.
Page 86
AFTER-COOLER REMOTE START INTERNAL LIGHTNING The internal lighting circuit is equipped with a timer. When the internal lighting is switched on, the timer is started. After a preset time the internal light will be switched off automatically. An integral after-cooler, with water separator (1), is The remote start allows the user to start, stop the available to reduce the outlet air temperature to compressor and switch to load/noload by radiosignal.
Technical specifications TORQUE VALUES GENERAL TORQUE VALUES CRITICAL TORQUE VALUES The following tables list the recommended torques applied for general applications Assemblies Torque value (Nm / lbf.ft) at assembly of the compressor. Axles to frame: Wheel nuts 270 (200) For hexagon screws and nuts with strength grade 8.8 Bolts, front axle/frame 205 (152) Bolts, rear axle/frame...
PERFORMANCE DATA At reference conditions, if applicable, and at normal shaft speed, unless otherwise stated. Designation XRXS 567 Cd - XRXS 607 Cd - XRVS 617 Cd - XRVS 647 Cd - XRXS 1240 CD7 XRXS 1275 CD7 XRVS 1300 CD7...
Page 90
Designation XRXS 567 Cd - XRXS 607 Cd - XRVS 617 Cd - XRVS 647 Cd - XRXS 1240 CD7 XRXS 1275 CD7 XRVS 1300 CD7 XRVS 1350 CD7 - at unload Fuel expert kg/h 32.9 32.9 30.0 31.1 lb/h 72.5...
3 281 1000 3 281 Temperature °C Temperature °C XRXS 567 Cd - XRXS 1240 CD7 XRVS 617 Cd - XRVS 1300 CD7 XRXS 607 Cd - XRXS 1275 CD7 XRVS 647 Cd - XRVS 1350 CD7 - 91 -...
DESIGN DATA Compressor Designation Number of compression stages Engine Designation All units Designation All units Make Caterpillar Capacity of oil sump: Type - Initial fill Coolant Liquid US gal 15.85 Number of cylinders - Refill (max.) Bore US gal 15.32 5.71 Capacity of cooling system Stroke...
Page 93
Unit Electric refuel pump Designation All units Designation All units Capacity of compressor oil Flow rate system US gal 21.66 US gal/m Net capacity of air receiver Self priming from dry up to US gal 37.78 Capacity of fuel tank (standard) Fuel temperature max 40 °C (104 °F) US gal 257.6...
Page 94
Compressor dimensions Designation All units Designation All units Dimensions (overall) L x W x H Weight (dry) Wagon towbar raised 5.40 x 2.25 x 2.51 Wagon 7200 inch 233.86 x 88.58 x 101.46 15875 Tandem EU 6.80 x 2.53 x 3.04 Tandem EU 8605 inch...
PARTS, SUBJECTED TO CAT. I AND COVERED BY THE MACHINE DIRECTIVE 89/392/EC All other parts PARTS, SUBJECTED TO ART. I, PARAGRAPH 3.3 All other parts - 97 -...
(for example sand, sawdust) and recyclable materials. dispose it according the applicable local disposal Your Atlas Copco compressor consists for the most regulations. Do not drain into the sewage system or part of metallic materials, that can be remelted in surface water.
Need help?
Do you have a question about the XRXS 567 Cd and is the answer not in the manual?
Questions and answers