Set for Remote Operation
Press the Settings View button
scroll to 1000 GENERAL SETTINGS
press Enter
scroll to 1100 OPERATION MODE COMMAND
Enter the OPERATION MODE COMMAND
menu
Enter the SETTINGS parameter
scroll to REMOTE
press Enter.
Now the controller can only be started/stopped/
loaded by means of Remote Start/Stop/Load digital
inputs.
The start/stop/load buttons at the control panel will be
inactive, and if pressed the display will show:
0.0
To deactivate Remote Operation:
Press the Settings View button
scroll to 1000 GENERAL SETTINGS
press Enter
scroll to 1100 OPERATION MODE COMMAND
press Enter
go to parameter SETTINGS
press Enter
scroll to LOCAL
press Enter.
Now press Back until you are in the Main View (or
the menu you require).
The Start/Stop/Load buttons at the control panel are
active.
- 52 -