Setting pre-settings
 By pressing button (1) once, twice or three times
you will select pre-set time 1, 2 or 3.
 The display shows e.g. pre-set time 1 and symbol
1. Set the pre-set period with buttons (2) or (3).
 With button (4) you can activate or deactivate the
pre-set period. When activated the symbol heating
is on appears and the symbol "1, 2 or 3".
Operation
The preheating time at -25°C is about 90
minutes.
Switching on the heater
 Press button (4). The heating period lasts
..minutes. The display shows: remaining heating
time and symbol 7.
Switching off the heater
 Press button (4). The heater will run idle for about
3 minutes. The display shows: actual time.
Continuous operation
 Press and hold button (3), then press button (4);
now the heater will be operating till button (4)
(heater off) is pressed.
Activating/ deactivating pre-set time
 Select pre-set time 1, 2 or 3 by pressing button (1).
 Activate the selected time by pressing button (4).
 The display shows the symbol heating is on as
well as the selected pre-set time, 1, 2 or 3.

BEFORE STARTING

(1)
1. Before initial start-up, prepare battery for
operation if not already done. See section
Recharging a battery.
2. Check that the draining caps in the spillage-free
frame are firmly tightened.
3. With the compressor standing level, check the
level of the engine oil. Add oil, if necessary, up to
the upper mark on the dipstick. Also check the
engine coolant level. Consult the Engine
Operation Manual for the type of coolant and type
and viscosity grade of the engine oil.
- 34 -
4. Remove the air receiver drain plug (1), see figure,
and open the valve to drain possible condensate.
Close the valve when oil comes out and reinstall
the drain plug. The interval between draining
operations may be determined by experience, as
the amount of condensate depends on the
operating condition.
Before
pressure is released.
5. Check the level of the compressor oil. See section
Check compressor oil level. The pointer of the
oil level gauge (OLG) should register in the green
(2)
range. Add oil if necessary. See section
Compressor oil for the oil to be used.
Before removing the oil filler plug (FP),
ensure that the pressure is released by
opening an air outlet valve.
6. Check that the fuel tank contains sufficient fuel.
Top up, if necessary. Consult the Engine
Operation Manual for the type of fuel.
7. Drain any water and sediment from the fuel filters
until clean fuel flows from the drain cock.
8. Empty the dust trap of each air filter (AF). See
section Replacing the filter element and the
safety cartridge.
draining,