Parameter
Transmit Unicast Packets
Transmit Multicast Packets
Transmit Broadcast Packets
Transmit Discarded Packets
Transmit Errors
Etherlike Statistics
Alignment Errors
Late Collisions
FCS Errors
Excessive Collisions
Single Collision Frames
Internal MAC Transmit Errors
Multiple Collision Frames
Carrier Sense Errors
SQE Test Errors
Frames Too Long
Deferred Transmissions
Internal MAC Receive Errors
Table 3-7 Port Statistics (Continued)
Description
The total number of packets that higher-level protocols requested be
transmitted to a subnetwork-unicast address, including those that were
discarded or not sent.
The total number of packets that higher-level protocols requested be
transmitted, and which were addressed to a multicast address at this
sub-layer, including those that were discarded or not sent.
The total number of packets that higher-level protocols requested be
transmitted, and which were addressed to a broadcast address at this
sub-layer, including those that were discarded or not sent.
The number of outbound packets which were chosen to be discarded
even though no errors had been detected to prevent their being
transmitted. One possible reason for discarding such a packet could
be to free up buffer space.
The number of outbound packets that could not be transmitted
because of errors.
The number of alignment errors (missynchronized data packets).
The number of times that a collision is detected later than 512 bit-times
into the transmission of a packet.
A count of frames received on a particular interface that are an integral
number of octets in length but do not pass the FCS check. This count
does not include frames received with frame-too-long or
frame-too-short error.
A count of frames for which transmission on a particular interface fails
due to excessive collisions. This counter does not increment when the
interface is operating in full-duplex mode.
The number of successfully transmitted frames for which transmission
is inhibited by exactly one collision.
A count of frames for which transmission on a particular interface fails
due to an internal MAC sublayer transmit error.
A count of successfully transmitted frames for which transmission is
inhibited by more than one collision.
The number of times that the carrier sense condition was lost or never
asserted when attempting to transmit a frame.
A count of times that the SQE TEST ERROR message is generated by
the PLS sublayer for a particular interface.
A count of frames received on a particular interface that exceed the
maximum permitted frame size.
A count of frames for which the first transmission attempt on a
particular interface is delayed because the medium was busy.
A count of frames for which reception on a particular interface fails due
to an internal MAC sublayer receive error.