Figure 14: Securing the rear angle brackets
7. Using a torque driver, torque the screws to 22 in/lb.
8. Connect the remaining ends of the PDU power cords to separate PDUs (if
Note:
Hewlett-Packard ships two PDU power cords with the Director.
9. Connect the equipment rack power cords to separate (for redundancy) facility
Director 2/64 Installation Guide
installed), as shown in
power cords.
Hewlett-Packard recommends installing an optional PDU in the rack.
WARNING:
Hewlett-Packard power cords are provided for each director
power supply. To prevent personal injury by electric shock, use only the
supplied power cords. Also, verify that the facility power receptacle is the
correct type, supplies the required voltage, and is properly grounded.
power sources, providing single-phase, 120 to 240 VAC current.
Figure
15; otherwise, connect the two standard AC
Installing and Configuring the Director