Removal and Replacement Procedures
To remove the component:
1. Be sure that the online and activity LEDs on the failed drive are both off.
2. Remove the failed drive.
2
To replace a hot-plug SCSI hard drive:
1. Slide the drive into the bay until it locks into place.
2. Close the lever.
3. Be sure that the drive LEDs illuminate one at a time and then turn off together to indicate
that the system has recognized the new drive.
In fault-tolerant configurations, allow the replacement drive to be reconstructed
automatically with data from the other drives. While reconstruction is in progress, the
online LED flashes.
2-6
HP CONFIDENTIAL Codename: Aurora Part Number: 251850-004 Last Saved On: 9/19/03 10:57 AM
CAUTION: To prevent improper cooling and thermal damage, do not operate the system
unless all bays are populated with either a component or a blank.