Troubleshooting Sflow Configuration; The Remote Sflow Collector Cannot Receive Sflow Packets - HP MSR Series Configuration Manual

Msr router series network management and monitoring
Hide thumbs Also See for MSR Series:
Table of Contents

Advertisement

# Configure parameters for an sFlow collector: specify sFlow collector ID 2, IP address 3.3.3.2,
the default port number, and description of netserver for the sFlow collector.
[Device] sflow collector 2 ip 3.3.3.2 description netserver
2.
Configure counter sampling:
# Set the counter sampling interval to 120 seconds.
[Device] interface ethernet 1/1
[Device-Ethernet1/1] sflow counter interval 120
# Specify sFlow collector 2 for counter sampling.
[Device-Ethernet1/1] sflow counter collector 2
3.
Configure flow sampling:
# Set the flow sampling mode and the sampling interval.
[Device-Ethernet1/1] sflow sampling-mode determine
[Device-Ethernet1/1] sflow sampling-rate 4000
# Specify sFlow collector 2 for flow sampling.
[Device-Ethernet1/1] sflow flow collector 2
# Display the sFlow configuration and operation information.
[Device-Ethernet1/1] display sflow
sFlow Version: 5
sFlow Global Information:
Agent
Collector Information:
ID
1
2
3
4
5
6
7
8
9
10
sFlow Port Information:
Interface CID
Eth1/1
The output shows that Ethernet 1/1 enabled with sFlow is active, the counter sampling interval is
120 seconds, and the packet sampling interval is 4000.

Troubleshooting sFlow configuration

The remote sFlow collector cannot receive sFlow packets

Symptom
The remote sFlow collector cannot receive sFlow packets.
IP:3.3.3.1(CLI)
IP
3.3.3.2
Interval(s) FID
2
120
Port
6343
6543
6343
6343
6343
6343
6343
6343
6343
6343
MaxHLen
Rate
2
128
4000
148
Aging
Size
Description
0
1400
N/A
1400
netserver
0
1400
0
1400
0
1400
0
1400
0
1400
0
1400
0
1400
0
1400
Mode
Status
Determine
Active

Advertisement

Table of Contents
loading

Table of Contents