If the maxim number is reached, the earliest history records are removed.
To configure the history records saving function:
Step
1.
Enter system view.
2.
Create an NQA
operation and enter
NQA operation view.
3.
Enter NQA operation
type view.
4.
Enable saving history
records for the NQA
operation.
5.
Set the lifetime of
history records.
6.
Configure the maximum
number of history
records that can be
saved.

Scheduling an NQA operation

The NQA operation works between the specified start time and the end time (the start time plus
operation duration). If the specified start time is ahead of the system time, the operation starts
immediately. If both the specified start and end time are ahead of the system time, the operation does not
start. To view the current system time, use the display clock command.
You can configure the maximum number of NQA operations that can work simultaneously as needed to
avoid excessive system resource consumption.
You cannot enter the operation type view or the operation view of a scheduled NQA operation.
A system time adjustment does not affect started or completed NQA operations. It only affects the NQA
operations that have not started.
To schedule an NQA operation:
Step
1.
Enter system view.
2.
Configure the scheduling
parameters for an NQA
operation.
3.
Configure the maximum number
of NQA operations that can
work simultaneously.
Command
system-view
nqa entry admin-name operation-tag
type { dhcp | dlsw | dns | ftp | http |
icmp-echo | snmp | tcp | udp-echo |
udp-jitter | voice }
history-record enable
history-record keep-time keep-time
history-record number number
Command
system-view
nqa schedule admin-name operation-tag
start-time { hh:mm:ss [ yyyy/mm/dd ] | now }
lifetime { lifetime | forever }
nqa agent max-concurrent number
121
Remarks
N/A
By default, no NQA operation
is created.
N/A
By default, this feature is not
enabled.
Optional.
By default, the history records in
the NQA operation are kept for
120 minutes.
Optional.
By default, the maximum
number of records that can be
saved for the NQA operation is
50.
Remarks
N/A
N/A
Optional.