G610 Pin#
9
49
7

3.11.1 VDD Reference Regulator

The G610 incorporates a regulated voltage output VDD. The regulator provides a 2.85V output
for use by the customer application. This regulator can source up to 30 mA of current to power any
external digital circuits.
When the G610 started up by power on signal, The VDD is output. So it can be Illustrating
module start up.
Important:
any current sourced through this regulator originates from the G610 BATT supply. The overall BATT
current consumed by G610 is directly affected by the VDD operation. The G610 current
consumption raises with respect to the current sourced through VDD.
Parameter
Vout
Iout
Imax
External
Capacitor
PSRR

3.11.2 External Reset

The RESET_N input signal would be power off the G610 immediately. This signal is set high
after power up, when G610 is operating. It is set low when G610 is powered off.
When the RESET_N signal is low, the G610 is powered off without the work net logging out.
Important:
G610 GPRS Module Hardware User Manual
G610 Signal name
VDD
LPG
RESET_N
The VDD regulator is powered from the G610's main power supply, and therefore
Conditions
Iout=30mA
Current pulled down from LDO
to GND until LDO voltage is
50% of nominal value
50 Hz - 20 kHz
It's recommended that it should connect he 1nF capacitor to GND on external
Description
LDO power output
Illustrating module start up
Module work status indicator
Extend reset module
Low level activated
Min
Typ
Max
-3%
2.85
3%
10
30
150
-35%
1
35%
35
Unit
V
mA
mA
uF
dB