Power Supply Adc; General Purpose Adc; Controls And Indicators Interface - Fibocom G610 Hardware User Manual

Gprs
Hide thumbs Also See for G610:
Table of Contents

Advertisement

lasted 8 samples are compared and averaged to provide a stable and valid result.
In Sleep mode, the ADC is stopped. When the G610 switch to Idle mode, the ADC should be
stable after 5mS.

3.10.1 Power Supply ADC

The main power supply (BATT) is sampled internally by the G610 ADC interface through a
dedicated input, which is not accessible on the interface connector. The G610 constantly monitors
the power supply for any low or high voltage.
Parameter
Supply Range
Resolution
Sampling Time
The ADC signals operation and reporting mechanism is defined by the AT+CBC command.

3.10.2 General Purpose ADC

The G610 provides 2 general purpose ADC signal for customer application use. The ADC
signal can monitor a separate external voltage and report its measured level independently to the
application, through the AT command interface.
G610 Pin#
19
20
Parameter
Input Voltage
Resolution
Sampling Time
The ADC signals operation and reporting mechanism is defined by the AT+MMAD command.

3.11 Controls and Indicators Interface

The G610 incorporates several interface signals for controlling and monitoring the module's
operation. The following paragraph describes these signals and their operation.
G610 GPRS Module Hardware User Manual
Conditions
Operating range
G610 Signal name
ADC2
ADC1
Conditions
Operating range
Min
Typ
3.20
1.0
Description
General purpose ADC
General purpose ADC
Min
Typ
0
0.5
Max
Unit
4.50
V
%
16
KHz
Max
Unit
1.00
V
%
16
KHz
Page 31 of 47