4.4.10.1 Zero Set

By inputting the MI signal for 30ms you set the current measurement value and the digital
display to zero.
There are two other ways to perform a zero set:
In run mode, press
Send the serial command RZS
For information on how the zero-set signal influences the system behavior, refer to the time
diagrams (see page 33).

4.4.10.2 Reset

By inputting the MI signal for 80ms you reset all measurement values and turn the judgment
outputs off.
NOTE
When the reset signal is input, the output data status becomes undefined
(see page 31). The analog output will either be the initial value of 11.000 [V]
or 21.6 [mA] or a predefined fixed value, depending on the setting of "Ana-
log Output Selection" (see page 66).
When you perform the reset by sending the serial command RRS, the mem-
ory will be cleared.
There are two other ways to perform a reset:
In run mode, press
Send the serial command RRS
For information on how the reset signal influences the system behavior, refer to the time dia-
grams (see page 33).