Specifications - Accelerated Care Plus Neuroprobe 500 Pro User Manual

Electrotherapy / infrared therapy system
Table of Contents

Advertisement

34
GENERAL:
Dimensions (with Probe):
Weight:
Operating Power:
Display System:
Push Buttons:
System Architecture:
STIMULATION SYSTEM:
Output:
Output Waveform:
Channel Isolation:
Line Linkage:
IFC MODES:
Full Field Burst Rate:
Rate Scan:
Vector:
Output:
PROBE SENSORY/MOTOR MODE:
Waveform:
Burst Rate:
Rate Scan:
Output:
PROBE NERVE BLOCK MODE:
Waveform:
Output:
PROBE NOXIOUS MODE:
Waveform:
Polarity:
Burst Rate:
Output:
INFRARED THERAPY MODE:
Waveform:
Pulse Rate:
COPYRIGHT © 2006 - 2017, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED

SPECIFICATIONS

8.0" (21cm) W x 12.0" (30cm) D x 3.5" (8.4cm) H
3lbs. 2oz. (1. 4kg.)
120 / 240 VAC; 50/60 Hz; 50W
Super Twist LCD full character display with adjustable contrast/viewing angle.
Conductive rubber with excellent tactile feel. Speed and sensitivity are fully adjustable.
Intel CMOS Integrated micro-controller with on board memory and instruction set.
Constant voltage up to maximum preset current limit.
AC square wave into resistive load, IFC FF 0-99 mA peak into 500 ohm load; Nerve Block mode
0 to 70 mA RMS current into a 500 ohm load; Probe Sensory, Motor 0-1.8 mA RMS 10k ohm
load Nerve block mode, O to 2.25 mA RMS current into a 10K ohm load. Noxious Mode 0-1.5
mA RMS 10K ohm load.
Independent transformer isolation
Less than 50 micro Amps when operated with the charger system
0.1 - 999 Hz
0 - 20 seconds, 0 - 50% modulation
- Scans amplitude of channel A from 0-maximum every 10 seconds relative to channel B,
which varies concurrently out of phase. Slow 90 - Scans amplitude of channel A from 0 - maximum
every 60 seconds relative to channel B, which varies concurrently out of phase. Fast 45 - Scans
amplitude of channel A from 50% to maximum every 10 seconds relative to channel B, which varies
concurrently out of phase. Slow 45 - Scans amplitude of channel A from 50% to maximum every 10
seconds relative to channel B, which varies concurrently out of phase.
IFC FF 0-99 mA peak into 500 ohm load, Nerve Block mode 0 to 70 mA RMS current into a 500
ohm load
AC square wave, 5000 Hz carrier frequency
Adjustable from .1 to 999 B.P.S., 50% duty factor
From 0-50% programmable with scan time from 0-20 seconds
0-1.8 mA RMS into 10K ohm load
AC square wave, 5000 Hz carrier frequency
0-2.25 mA RMS into 10K ohm load
Monophasic or Biphasic Square wave pulsed current 50% duty factor
+, - or +/- every alternate pulse
Adjustable from DC to 15 Hz, 50% duty factor
0-1.5 mA Peak current into 10K ohm load
Square wave 50% duty factor
45.4, 62.5and 83.3 KHz at 50% duty factor 1 min per frequency
®
NEUROPROBE
500 PRO USER MANUAL