The Neuroprobe ® 500 Pro; Delivery Of The Neuroprobe 500 Pro; Introduction - Accelerated Care Plus Neuroprobe 500 Pro User Manual

Electrotherapy / infrared therapy system
Table of Contents

Advertisement

®
NEUROPROBE
500 PRO USER MANUAL
Upon receipt of your Neuroprobe
damage. All ACP products are packaged carefully for rapid, safe delivery. We guarantee delivery in perfect
condition to the postal or delivery services; however, any damage or loss incurred during transportation or delivery
is the postal or Delivery Company's responsibility. If damage or loss to the product and/or container is obvious or
suspected, appropriate notation must be made on the signed freight bill at the time of delivery. All damage claims
should be promptly filed with the delivering carrier and must be initiated by the addressee where the package was to
be delivered. Retain the original shipping container and inserts for validation of damage claim or use at a later date.
Unpack and check all accessories. A list of enclosed accessories is provided with each unit to assist you in
identifying the type and number of accessories.
NOTE: The purpose of this manual is to acquaint you with the Neuroprobe
functionality. Please read the manual carefully before attempting to operate the Neuroprobe
questions remain unanswered, contact your local ACP representative, or call 1-800-350-1100. Outside the
USA, call 1-775-685-4000.
®
The Neuroprobe
500 Pro gives the clinician the option of using any combination of an Estim probe, Interferential Current
in bipolar or quadripolar modes, or Monochromatic Infrared Therapy to reduce pain and increase circulation.
Flexible neoprene pads deliver heat and Infrared therapy through multiple clusters of infrared and red visible super
luminous diodes (SLD). The SLD cluster pads are contoured and designed for fast set-up over key nerves, arteries
and acu/trigger points.
®
The Neuroprobe
500 Pro offers audio and visual detection of acu/trigger points and is designed to provide Infrared
therapy, sensory, motor, noxious, and nerve block stimulation techniques for advanced pain management. Its two
separate generators produce medium frequency 5000 Hz alternating currents in continuous or modulated modes.
Two isolated output circuits with independent intensity controls are provided. The output of each circuit is easily
determined in milliamps or micro amps through the display screen. A probe mode and point locator is built into the
system to detect areas of low skin resistance and trigger points. The digital timer allows the operator to select the
length of the total treatment time and to monitor the time remaining in minutes.
®
The Neuroprobe
500 Pro offers Full Field (FF) Interferential Current (IFC) therapy. An interferential vector
scanning mode can be turned off or on for stationary or continuous movement of the interferential field.
500 Pro's optional probe with fully adjustable parameters provides a wide variety of uses for pain
®
The Neuroprobe
management with trigger point stimulation for pain control.
®
The Neuroprobe
500 Pro provides a nerve block mode through treatment pads with high output capable of sensory
nerve block, or through the optional probe to produce local trigger point anesthesia.
COPYRIGHT © 2006 - 2017, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED
THE NEUROPROBE
Delivery of the Neuroprobe
®
500 Pro inspect the shipping container and contents for any obvious or concealed

Introduction

®
500 PRO
®
500 Pro
®
500 Pro's operating features and
9
®
500 Pro. If

Advertisement

Table of Contents
loading

This manual is also suitable for:

140500b

Table of Contents