- 44 -
GENERAL:
Dimensions:
Weight
(Including batteries):
Operating Power:
Battery Life:
Display System:
Push Buttons:
System Memory:
System Architecture:
STIMULATION SYSTEM:
Output:
Output Waveform:
Channel Isolation:
Line Leakage:
MFAC (MEDIUM FREQUENCY ALTERNATING CURRENT) MODE:
Waveform:
Burst Rate:
Rate Scan:
LVPC (LOW VOLTAGE PULSED CURRENT) MODE:
Waveform:
Phase Duration:
Pulse Rate:
IFC (INTERFERENTIAL CURRENT) MODE:
Frequency Difference Rate:
Full Field Burst Rate:
Rate Scan:
Vector:
PENS (PATTERNED ELECTRICAL NEUROMUSCULAR STIMULATION) MODE:
Waveform:
Phase Duration:
Pulse Rate:
COPYRIGHT © 2004 - 2017, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED

TECHNICAL SPECIFICATIONS

12" (30 cm) D x 6.5" (16.5cm) W x 3" (7.6cm) H
3lbs. 14oz. (1.75kgs)
120/240VAC; 50/60Hz; 50W, 4 x 1.5VDC "D" cell alkaline or rechargeable batteries.
New alkaline batteries operate the system for 40 hours at full output and over 100 hours at normal settings.
Battery voltage is displayed and monitored. With the 4.4Ah NiCad rechargeable cells the system will
operate approximately 10 hours at normal settings.
Super Twist LCD full character display with adjustable contrast /viewing angle.
Polyester embossed overlay for tactile feel and infection control. Speed and sensitivity are fully adjustable.
The system remembers all prior custom settings from treatment to treatment in active battery powered
RAM memory. (Must be reset if the batteries are changed or discharged.)
CMOS integrated micro-controller with on board memory and instruction set.
Constant voltage up to maximum preset current limit
AC sine wave into physiologic load, IFC and MFAC modes, and biphasic square wave (LVPC) or mono-
phasic pulsed current (HVPC mode). Output Amplitude: IFC FD and NMES modes-0 to 70 mA RMS
current into a 500Ω, LVPC mode 75mA P-P, HVPC mode 250VDC peak into 500Ω loads.
Independent transformer isolation.
<50 µA when operated with the charger system.
Modified sine wave into physiologic load 2 KHz, 2.5 KHz, 4 KHz , 5 KHz AND 10 KHz carrier frequency.
Adjustable from 0.1 to 250bps, 50% duty factor
From 0-50%, from 0-20 seconds
Asymmetrical biphasic square wave
10 - 300 µs
0.1 – 250 pps
Output channel A, fixed at 2.0 KHz, 2.5, KHz, 4.0 KHz, or 5.0 KHz. Output channel B variable from
channel A frequency + .0 to 250 Hz. Beat rate may be set during treatment.
.1 – 250 Hz
0-20 seconds, 0-50% modulation. Upper and lower frequencies are fully programmable and sweep time is
adjustable in set mode.
Scans amplitude of channel A relative to channel B which varies concurrently out of phase.
Asymmetric Biphasic
Variable from 40 µs to 100 µs
Set at 50 Hz
®
2
OMNISTIM