GENERAL  M AINTENANCE 
1.  Wipe down all areas in the sweat path with a damp cloth after each workout. 
2.  If a squeak, thump, clicking or rough feeling develops the main cause is most likely one of two 
reasons: 
I.  The hardware was not sufficiently tightened during assembly. All bolts that were installed 
during assembly need to be tightened as much as possible. It may be necessary to use a 
larger wrench than the one provided if you cannot tighten the bolts sufficiently. I cannot 
stress this point enough; 90% of calls to the service department for noise issues can be 
traced to lose hardware or the rear rails being dirty. 
II.  Dirt build‐up on the rear rails and polyurethane wheels are also a source of noise. Noise 
from build‐up on the rails can cause a thumping sound that you would swear is coming from 
inside the main body of the machine because noise travels, and is amplified in the tubing of 
the frame. Clean the rails and wheels with a lint free cloth and rubbing alcohol. Stubborn 
build‐up can be removed with your thumbnail or a non‐metallic scraper, like the back edge 
of a plastic knife. After cleaning, apply a small amount of lubricant on the rails with your 
fingers or a lint free cloth. You only need a thin coat of lubrication, wipe off any excess. 
3.  If squeaks or other noises persist, check that the unit is properly leveled before calling the 
service department. 
 
ELLIPTICAL NOISES 
Your new elliptical is engineered and manufactured to the strictest industry standards and tolerances. 
All elliptical trainers, no matter who the manufacturer, have a multitude of moving linkages and parts. 
Be aware that even with the tightest mechanical tolerances there still could be a slight amount of play 
between some parts. This inherent play can result in slight noises during use such as clicks and small 
thumps. Please expect that the elliptical will not be completely silent. 
 
MAINTENANCE MENU IN CONSOLE SOFTWARE 
The console has built in maintenance/diagnostic software. The software will allow you to change the 
console settings from English (imperial) to Metric and turn off the beeping of the speaker when a 
key is pressed for example. To enter the Maintenance Menu (may be called Engineering Mode, 
depending on version) press and hold down the Start, Stop and Enter keys keep holding the keys 
down for about 5 seconds and the Message Window will display  " Engineering Mode". Press the Enter 
button to access the menu below. Press the Level ▲/▼ keys to navigate the menu. 
 
A. 
Key Test ‐ Will allow you to test all the keys to make sure they are functioning. 
B. 
Display Test ‐ Automatically tests all LCD's. 
C. 
Functions ‐ Press Enter to access settings, use Level 
I.
ODO Reset ‐ Resets the odometer. 
II.
Units ‐ Choose from English (Imperial) or Metric display readings. 
III.
Display Mode ‐ Turn off to have the console power down automatically after 30 minutes of      
               Inactivity. 
IV.
Motor Test ‐ Continually runs the tensioning gear motor. 
V.
Manual ‐ verifying every resistance level that unit has to offer. 
VI.
Pause Mode ‐ Turn on to allow 5 minutes of pause, turn off to have console pause indefinitely 
VII.
Key Tone ‐ Turn on or off the beep sound when a key is pressed. 
D. 
Security ‐ Allows you to lock the keypad so no unauthorized use of the machine is allowed. When 
the child lock is enabled, the console will not allow the keypad to operate unless you press and 
hold the Start and Enter buttons for 3 seconds to unlock the console. 
E. 
Factory Set 
F. 
Exit ‐ Select to exit Maintenance Menu. 