Freq.
DCR
100/
120Hz
1kHz
10kHz
100kHz
Note: All accuracy is guaranteed by proper ratio resistor calibration and open/short calibration.
If D > 0.1, the accuracy should be multiplied by
1
Z
=
if D << 0.1 in capacitance mode
C
π
2
fc
Z
= 2πf L if D << 0.1 in inductance mode
L
6
Z
0.1- 1Ω
1 – 10Ω
1.0%+5d
0.5%+3d
1.0%+5d
0.5%+3d
1.0%+5d
0.5%+3d
1.0%+5d
0.5%+3d
2.0%+5d
1.0%+5d
1 D
10 –
100k –
100kΩ
1MΩ
0.3%+2d
0.5%+3d
1.0%+5d
0.3%+2d
0.5%+3d
1.0%+5d
0.3%+2d
0.5%+3d
1.0%+5d
0.3%+2d
0.5%+3d
2.0%+5d
0.5%+3d
1.0%+5d
2.0%+5d (1M – 2MΩ)
+
2
1M –
20Μ−
Remark
20ΜΩ
200MΩ
2.0%+5d
2.0%+5d
D < 0.1
5.0%+5d
N/A