2-62
INSTALLATION
SNMP Network Setup
SNMP mib File Location
SNMP Default Settings
SNMP Features
To set up SNMP, you must run Optimod-PC control software on the same computer
that houses the Optimod-PC card(s) being monitored by SNMP. SNMP runs as part of
the same Windows Service that manages communication between Optimod-PC, your
computer, and your network.
In the S
menu, select S
ERVICE
trols (Figure 2-11).
•
SNMP (Enable/Disable): enables or disables the SNMP feature.
•
Primary Manager Address: sets the address of the Primary SNMP Manager.
•
Primary Manager Port: sets the port of the Primary SNMP Manager.
When SNMP is enabled, you can disable the primary or secondary man-
ager by setting its port to 0.
•
Secondary Manger Address: sets the address of a Secondary SNMP Manager.
•
Secondary Manger Port: sets the address of a Secondary SNMP Port.
The default 1101 install location is:
\Program Files\Orban\Optimod-PC 1101\orban1101.mib
or
C\Program Files(x86)\Orban\Optimod-PC 1101\orban1101.mib
•
SNMP Agent: Disabled
•
Primary Manager(Alarm) Address: 192.168.254.254
•
Primary Manager (Alarm) Port: 0
•
Secondary Manger (Alarm) Address: 192.168.254.254
•
Secondary Manger (Alarm) Port: 0
Get/Query:
•
Card name
•
Card serial number
•
Software version
to access the SNMP configuration con-
S
ERVICE
ETTINGS
ORBAN MODEL 1101