Wiring Recommendations

Signal
RS-485 Comm, two wire
Power (22 gauge)
Power (18 gauge)
RJ45-Ethernet
CAN Bus
Fire Alarm Relay
Request-to-Exit
Door Contact
Transformer Block
Molex Connector
Earth ground
Reader Option 1 (22 AWG)
Reader Option 2 (20 AWG)
Reader Option 3 (18 AWG)

Additional Resources

The following additional resources are available for the installer as well as the client.
Panel Networking Admin Interface Guide
Reader/Keypad Wiring Guide
Installation Worksheet: Network
Installation Worksheet: Door Board
Installation Worksheet: Input Output Board
Brivo Onair Quick Start Guide
Brivo Cellular Network Router Configuration Guide
Brivo Onsite Server Quick Start Guide
Technical Support: 1-866-BRIVO-4-U
www.brivo.com
© 2017 Brivo Systems LLC. All rights reserved.
Belden # or
AWG
Equivalent
9841
24
5504FE
22
6300FE
18
N/A
Cat5
N/A
Cat 5
6300FE
18
5520FE/6300FE
22/18
5500FE
22
6300FE
18
N/A
22
N/A
6
5504FE
22
5400FE
20
6300FE
18
6
Brivo ACS6000 Installation Manual
Twisted
Conductor
Shielded?
Pair
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
P-MAN-PUB-ACS6000 Installation Manual
Max Length
Yes
4000 ft
Yes
600 ft
Yes
1500 ft
Yes
1500 ft
Yes
1500 ft
Yes
1500 ft
Yes
1500 ft
Yes
1500 ft
Yes
100 ft
No
1 ft
Yes
20 to 40 ft
Yes
250 ft
Yes
300 ft
Yes
500 ft