Wire The Ac/Dc Transformer To The Power Supply - Brivo ACS6000 Installation Manual

Hide thumbs Also See for ACS6000:
Table of Contents

Advertisement

Wire the AC/DC transformer to the power supply

WARNING: Transform Connection
DO NOT CONNECT THE TRANSFORMER TO A SWITCHED OUTLET OR OTHERWISE
CONTROLLED AC OUTLET.
DO NOT CONNECT THE TRANSFORMER TO THE 120 VAC OUTLET UNTIL ALL
WIRING IS COMPLETED.
1. The transformer block comes pre-wired with 10 feet of cable. If an extension is needed, use 18
AWG wire (minimum grade) to connect to the 16VAC/19VDC POWER INPUT terminal block on
the power supply board, using terminals DC +/AC1 and DC -/AC2.
2. To maintain UL compliance, the unit must be powered by a UL 294 Listed power supply capable
of supplying 16VAC/19VDC, 2.1A to the power supply board.
Model
Brivo ACS6000-A/ACS6008-A
Brivo ACS6000-E/ACS6008-E
© 2017 Brivo Systems LLC. All rights reserved.
Figure 9 - Connect AC Transformer to Power Supply
Circuit
Voltage (VDC/AC)
120/240VAC (Primary)
(This voltage is supplied
to the wall transformer
and not directly to any
Input
PCBs inside of the
19VDC (Secondary)
16VAC (Secondary)
21
Brivo ACS6000 Installation Manual
Current (mA/A)
0.49A/1.0A
chassis)
1.89A (DC)
2.25 A (RMS)
P-MAN-PUB-ACS6000 Installation Manual