Rs-485/Wiegand Switch Locations - Brivo ACS6000 Installation Manual

Hide thumbs Also See for ACS6000:
Table of Contents

Advertisement

a) The IN1 and IN2 terminals are contact closure type inputs that share a COM terminal.
b) The terminals can be used for a variety of purposes, and are programmed through the
application.
6. Wire the Reader terminals to the last block of terminals in this door node.
NOTE: To activate RS-485 functionality on the ACS6000 MAIN BOARD for Door 1,
put the RS-485/Wiegand Door 1 switch in the RS-485 position. For Door 2, put the
RS-485/Wiegand Door 2 switch into the RS-485 position.
To activate Wiegand functionality on the ACS6000 MAIN BOARD for Door 1, put
the RS-485/Wiegand Door 1 switch in the Wiegand position. For Door 2, put the
RS-485/Wiegand Door 2 switch in the Wiegand position.
NOTE: The ACS6000 board defaults to Half-Duplex communication when using RS-
485 reader functionality. In order to switch to Full-Duplex communication, move
the Door 1 FDX/HDX switch on Door 1 and Door 2 FDX/HDX switch on Door 2 to
the Full-Duplex position.
If placing into Full-Duplex mode, be careful as most readers will typically operate in
Half-Duplex mode.
NOTE: To activate Full Duplex functionality on the ACS6000 MAIN BOARD for Door
1, put the FDX/HDX Door 1 switch in the FDX position. For Door 2, put the FDX/HDX
Door 2 switch into the FDX position.
To activate Half Duplex functionality on the ACS6000 MAIN BOARD for Door 1, put
the FDX/HDX Door 1 switch in the HDX position. For Door 2, put the FDX/HDX Door
2 switch in the HDX position.
© 2017 Brivo Systems LLC. All rights reserved.
Figure 15 - RS-485/Wiegand Switch Locations
28
Brivo ACS6000 Installation Manual
P-MAN-PUB-ACS6000 Installation Manual