Total number of downstream interfaces: 1
1: Tunnel1, 192.168.0.3
The output shows that tunnel interface tunnel1 (192.168.0.3) on Spoke 1 will receive the multicast
data addressed to multicast group 225.1.1.1 from the source.

Troubleshooting multicast routing and forwarding

Static multicast route failure

Symptom
No dynamic routing protocol is enabled on the routers, and the physical status and link layer status of
interfaces are both up, but the static multicast route fails.
Solution
To resolve the problem:
1.
Use the display multicast routing-table static command to display information about static
multicast routes. Verify that the static multicast route has been correctly configured and that the
route entry exists in the static multicast routing table.
2.
Check the type of interface that connects the static multicast route to the RPF neighbor. If the
interface is not a point-to-point interface, be sure to specify the address for the RPF neighbor.
3.
If the problem persists, contact Hewlett Packard Enterprise Support.
Protocol: pim-sm, UpTime: 00:00:02, Expires: 00:03:28