Server System R1000WF Product Family System Integration and Service Guide
2.6

Drive Carrier Extraction, Installation, and Assembly

The 1U server product family has front drive bay chassis options that support 2.5" form factor drives (Hard
Disk Drives or Solid State Drives) or 3.5" form factor hard disk drives with the option to support 2.5" SSDs.
This section provides instruction for drive extraction from the chassis, drive installation into the chassis, and
drive assembly.
Note: To maintain proper system cooling, all externally accessible drive bays must be populated with a drive
carrier. Each drive carrier must have installed a hard disk drive (HDD), Solid State Device (SSD), or a supplied
drive blank.
2.6.1

Drive Carrier Extraction

1. Remove the drive carrier from the chassis by first pressing the button on the carrier face plate to release
the lever (see Letter "A").
2. Using the lever, pull the carrier from the drive bay (see Letter "B").
2.6.2

Drive Carrier Installation

1. Align the drive assembly with the open drive bay
2. With the lever in the open position, insert the drive assembly into the drive bay (See letter "A") and push
forward until the drive makes contact with the backplane
3. Complete the drive installation by closing the drive assembly lever until it locks into place (See letter "B")
28
PRESS
Figure 44. Extracting Drive Carrier from Chassis
Figure 45. Installing Drive Carrier into Chassis